background image

 

 

 

 

Step 3. Water Fill 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

WARNING:

 To reduce the risk of fire 

or shock hazard, do not pour or spill 
water into control or motor area. If 
controls get wet, let them dry 
completely and have unit checked 
by qualified service personnel before 
plugging in. 

After the humidifier is positioned 
where it will be operating, you are 
ready to fill the humidifier. The bottle 
tilts out and away from the base. 
Take care not to bump or damage fill 
valve assembly on the bottom of the 
bottle. 
 
Invert the bottle. Press the valve 
stem button into the bottle and turn 
clockwise to lock in open position. 
Place bottle under the faucet. Fill the 
bottle, being careful not to allow any 
debris to get in the valve seating. 
Once the bottle is full, press the 
valve stem button and turn counter 
clockwise to release and close

CAUTION:

 Use only 32-14900 EPA 

Registered Bacteriostat from Sears.  

Under no circumstances 

should you  

use water treatment products designed 
for Rotobelt or Ultrasonic humidifiers. 

Place the water bottle back into the 
humidifier base. When positioned 
properly, the plunger will open and 
the water will flow into the base. The 
base will hold the entire contents of 
the water bottle. Once the bottle is 
empty, remove it and repeat the 
filling process. The humidifier is now 
filled to capacity. For less frequent 
filling let the humidifier exhaust both 
the water from the bottle and the 
base before filling. 

 

 

 

27 

Limpieza y mantenimiento  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ADVERTENCIA:

 para reducir el 

riesgo de lesiones, incendios o 
daños al humidificador, utilice 
solamente limpiadores 
recomendados específicamente 
para humidificadores. Nunca utilice 
materiales inflamables, 
combustibles ni venenosos para 
limpiar su humidificador. Para 
reducir el riesgo de quemaduras y 
daños al humidificador, nunca 
coloque agua caliente en el 
humidificador. 

ADVERTENCIA:

para reducir el 

riesgo de descarga, siempre 
desenchufe el humidificador 
antes de limpiarlo o de efectuar 
reparaciones. Si el humidificador 
no está desenchufado,  el 
ventilador puede arrancar 
después de que  se retire el 
alojamiento. 

Paso 2 

Remoción de partes 

Consulte “Reemplazo y cuidado del 
filtro” en la página 10. 

OBSERVACIÓN:

 puede haber todavía 

un poco de agua en la base. Con 
cuidado elimine el agua o retírela con 
una esponja. 

Paso 1 

Para facilitar la limpieza, la base del 
humidificador debe estar vacía y 
completamente seca. Para lograr esto, 
use el siguiente método:

 

a.  Deje que el humidificador 

funcione hasta que el 
mensaje de LLENADO “F”  
se ilumine y el apagado 
automático detenga el 
ventilador del humidificador. 

b

Desenchufe el humidificador

PRECAUCIÓN:

 La pureza del 

agua local varía según el área y, 
en ciertas condiciones, las 
impurezas del agua y las bacterias 
en el aire pueden promover el 
crecimiento de microorganismos 
en el depósito del humidificador. 
Para retardar el crecimiento de 
bacterias que puedan causar 
olores y ser perjudiciales para su 
salud, utilice solamente los filtros 
de reemplazo recomendados. 
También recomendamos usar el 
bactericida aprobado EPA 32-
14900 de Sears y el limpiador de 
humidificadores, disponibles en su 
tienda local minorista. 

Summary of Contents for 758.17006

Page 1: ...e TOWER HUMIDIFIER 6 Gallon Output with Digital Readout Model 758 17006 CAUTION Before using this product read this manual and follow all its Safety Rules and Operating Instructions Safety Assembly Operation Maintenance Parts Español pg 17 Sears Roebuck and Co Hoffman Estates IL U S A ww sears com Part No 1B71756 Printed in China ...

Page 2: ...so de un año desde la fecha de compra devuélvalo a cualquier tienda Sears Repuestos Sears y Centro de Servicios de Reparación u otra tienda de Kenmore para que lo reparen gratuitamente Si se utiliza alguna vez este aparato con fines que no sean familiares esta garantía tendrá validez sólo por 90 días desde la fecha de compra Esta garantía cubre solamente defectos de los materiales y mano de obra S...

Page 3: ...mblaje del control o el motor puede provocar un peligro a menos que la reparación sea realizada por un técnico de servicios calificado El servicio de reparaciones está disponible en la tienda Sears más cercana u otra tienda de Kenmore para que lo reparen gratuitamente 3 KNOW YOUR HUMIDIFIER Based on an area with average insulation and an 8 foot ceiling height Description Gallon Output 24 hrs Capac...

Page 4: ... de AJUSTE es del 65 El nivel de humedad del AMBIENTE no alcanzó el 1 o más por encima del nivel de humedad de AJUSTE Un porcentaje de humedad de ajuste del 65 hace que el ventilador funcione continuamente Regule el nivel de AJUSTE entre el 25 y el 60 Déjelo funcionar hasta que se alcance el nivel de humedad deseado Esto puede tardar hasta 48 horas inicialmente Escasa evaporación de agua Se encien...

Page 5: ...rada OBSERVACIÓN también se recomienda el procedimiento de Mantenimiento quincenal si no va a utilizar el humidificador durante una semana o más 5 Positioning the Unit The humidifier should be positioned with the back cord exit side and sides at least 2 inches away from the wall Air needs to enter through all of the louvers in the housing assembly in order for the humidifier to operate at peak eff...

Page 6: ...ra reducir el riesgo de lesiones incendios o daños al humidificador utilice solamente limpiadores recomendados específicamente para humidificadores Nunca utilice materiales inflamables combustibles ni venenosos para limpiar su humidificador Para reducir el riesgo de quemaduras y daños al humidificador nunca coloque agua caliente en el humidificador ADVERTENCIA para reducir el riesgo de descarga si...

Page 7: ...la base primero colocando los ganchos ubicados cerca de la parte frontal de la base en los orificios de contacto en el alojamiento superior y luego inclinando el alojamiento superior hacia la base hasta que la traba de la parte trasera se conecte al alojamiento principal 8 Vuelva a colocar el humidificador en su posición de funcionamiento 9 El humidificador está ahora listo para ser llenado para s...

Page 8: ...moho Si no se desea el MODO DE SECADO llene el humidificador con agua y el ventilador volverá a la velocidad determinada OBSERVACIÓN el ventilador cambiará automáticamente a la velocidad más baja durante el MODO DE SECADO Humidistato El humidistato ubicado en el cable detecta el porcentaje de humedad en el aire Hace que el humidificador se encienda y se apague para mantener el punto de AJUSTE de h...

Page 9: ...cionando a la velocidad más baja hasta que el filtro se seque 9 NOTE During this time the room humidity level will continue to be monitored and the humidifier will cycle the fan on and off until the filter is completely dry The fan will shut off leaving you with a dry humidifier that is less prone to mold and mildew growth If DRY OUT MODE is not desired refill the humidifier with water and the fan...

Page 10: ...ousing 8 Reposition the humidifier to its operating position 9 The humidifier is now ready to be filled for operation 23 Cuando la temperatura exterior es de La humedad relativa interior recomendada es del 10 F 24 C 20 2 F 18 C 25 10 F 12 C 30 20 F 6 C 35 Paso 4 Configuración de los controles Los niveles de humedad deseados que establezca dependerán de su nivel de comodidad personal temperatura ex...

Page 11: ... que el humidificador termine el agua de la botella y de la base antes de llenarlo PRECAUCIÓN Utilice solamente el bactericida registrado 32 14900 EPA de Sears Bajo ninguna circunstancia utilice productos de tratamiento de agua diseñados para humidificadores Rotobelt o Ultrasonic 11 Cleaning and Maintenance WARNING To reduce the risk of injury fire or damage to humidifier use only cleaners specifi...

Page 12: ...l enchufe de ninguna manera OBSERVACIÓN debido a que el humidificador libera aire húmedo frío es mejor dirigir el flujo de aire lejos del termostato y de las fuentes de calor y colocar los humidificadores junto a una pared interior La unidad no se debe colocar donde el aire frío proveniente de paredes externas o el aire tibio proveniente de una fuente de aire caliente la alcancen directamente Para...

Page 13: ... not illuminated No Power Power button has not been depressed Check 120 volt power source Press power button once to turn on Fan not operating digital display is illuminated ROOM humidity level is not 3 more below SET humidity level Reservoir is empty Raise SET humidity level if desired Increase fan speed Fill humidifier with water Fan running continuously SET humidity level is 65 ROOM humidity le...

Page 14: ... is done by a qualified service technician Repair service is available at your nearest Sears store or Sears Parts Repair Service Center 19 SOBRE SU HUMIDIFICADOR Basado en una superficie con aislamiento promedio y una altura de cielorraso de 8 pies Descripción Rendimiento de galones durante 24 horas Capacidad de la botella Capacidad de la base Cobertura en pies cuadrados Velocidades del ventilador...

Page 15: ...reducir el riesgo de incendio no lo utilice cerca de una fuente de fuego abierta como una vela u otra fuente 12 Preste atención a la etiqueta de advertencia que aparece adjunta 15 One Year Limited Warranty When installed operated and maintained according to all instructions supplied with the product if this appliance fails due to a defect in material and workmanship within one year from the date o...

Page 16: ...____________ _________________________________________ _________________________________________ _________________________________________ _________________________________________ _________________________________________ 17 LEA Y GUARDE ESTAS INSTRUCCIONES Guía de uso y cuidado HUMIDIFICADOR TIPO TORRE Rendimiento de 6 galones con lector digital Modelo 758 17006 PRECAUCIÓN antes de usar este pro...

Reviews: