background image

Summary of Contents for 79041273000

Page 1: ...djacent and overhead cabinetry is 30 76 2 cm 30 76 2 cm min for unprotected cabinet 24 61 cm min for protected surface Cooktop Cutout Dimensions 4 tl 8 ff C X 10 2 cm x 20 3 cm opening at the right rear to route armored cable if a panei is present F Figure 1 30 Model shown only 30 Ceramic Model 36 Ceramic Model 30 Ceramic Model 36 Ceramic Model 303 78 1 363 93 3 29 5 8 75 2 35 5 8 90 5 211 2 54 6 ...

Page 2: ...tion of Junction Box I 12 30 5 cm J Min From Edge of Cooktop to Nearest Combustible Wall Either Side of Unit It is not recommended to use drawer underneath cooktop Empty space is needed for installation purpose Letters on this figure refer to chart on front page except for J K To eliminate the risk of burns or fire by reaching over heated surfaces cabinet storage space located above the cooktop sh...

Page 3: ...ed as shown in Figure 2 with as much slack as possible remaining in the cable between the box and the appliance so it can be moved if servicing is ever necessary 3 A suitable strain relief must be provided to attach the flexible armored cable to the junction box Observe aH governing codes and local ordinances Unpacking Instructions 1 Leave corner supports on cooktop until completion of Electrical ...

Page 4: ... other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch clrcult neutral conductor in usual manner see Figure 6 or 7 If your appliance is to be connected to a 3 wire grounded junction box US only where local code permit connecting the appllance groundlng conductor to the neutral white see Figure 4 or 5 NOTE TO ELECTRICIAN The armored cable leads suppl...

Page 5: ...e from Power Supply White Wire Black Wires Junction Box Ground Wire U L Listed Conduit Bare or Green Wire Connector or CSA listed Cable from appliance Figure 6 4 WIRE GROUNDED JUNCTION BOX if your cooktop has a 4 wire cable see figure 7 1 Disconnect the power supply 2 Separate the green or bare copper and white appliance cable wires 3 In the circuit breaker fuse box or junction box connect applian...

Page 6: ...plate is located under the cooktop When ordering parts for or making inquiries about your cooktop always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your cooktop Before You Call for Service Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide It may save you time and expense The list includes co...

Page 7: ...cooktop to junction box Approx 3 _ 208 240Volt 7 5cm _ junction box for cooktop Cabinet side fliier panels are necessary to isolate the unit from adjoining cabinets Cabinet side filler height should allow for installation of ap proved cooktop models 36 Min 91 4cm Min Unit will overlap minimum edges by 1 2 5cm Use 3 4 1 9cm plywood installed on two runners flush with toe plate Base must be capable ...

Page 8: ...Notes 8 ...

Page 9: ...rficie de la estufa y los cjabinetes adyacentes y por encima son de 30 76 2 cm 30 76 2 cm min para un cjabinete desprotecjido 24 61 cm min para una superficie protecjida Dimensiones del Recortado de la Estufa C 4 1 x 8 10 2 cenfimetros x 20 3 cenfimetros apertura en la parte posterior derecha para encaminar el cable armado si un panel est6 presente Modelo 30 303 78 1 211 2 54 6 31 4 8 3 Modelo 36 ...

Page 10: ...o F 2 1 2 6 4 cm min desde el borde delantero dei corte hasta el borde delantero de la parte superior dei armario Ubicaci6n aproximada de ia caja de empaimes I 12 30 5 cm J min desde el borde del hasta el compartimiento de combustible ambos iados del artefacto No es recomendabJe utilizar cajones debajo de la estufa Para ias dimensiones J y I v4ase ia tabia en ia p6gina 1 Para evitar riesgos de que...

Page 11: ...e cable coma sea posibie en tre la caja y el electrodom_stico r de forma que asi el electrodom6stico se pueda mover f_lciJmente r si fuera necesario para hacer una reparaci6n 4 Se debe de usar un conectador que reduzca Ja tirantez de una forma adecuada para unir el cable blindado flexible a la caja de empalme Instrucciones de clesembalaje 1 Deje los soportes de las esquinas en la estufa hasta la t...

Page 12: ...ales o donde los c6dlgos locales no permltan poner a tlerra medlante el neutro blanco o en Canad6 desconectar la conexi6n blanca de la verde V utillzar la conexi6n a tlerra para poner a tlerra la unldad de acuerdo a los c6dlgos locales conectar el neutro al clrculto de blfurcaci6n conductor neutro de manera usual Vet Figura 6 o 7 St su electrodom stlco va a set conectado a una caja de conexi6n pue...

Page 13: ...interruptor autom6fico caja de fusibles o caja de juntas conectar el aparato y los cables residen dales como se muestra en la figura 6 Cable desde el suministro de energ a Alambre desnudo _Alambre blanco Si su cocina tiene un cable de 4 hilos ver figura 7 1 Desconecte el suministro el_ctrico 2 Separe el aJambre verde o cobre desnudo y eJ alambre blanco del electrodom6stico 4 En el interruptor auto...

Page 14: ... rondo de la estufa Cuando haga pedidos de repuestos o solicite informaci6n con respecto a su estufa est_ siempre seguro de incluir el nOmero de modelo y de serie y el nOmero o letra del Iote de la placa de serie de su horno Antes de llamar al servicio Lea la secci6n Lista de Control de Averias en su Manual del Usuarlo Esto le podr6 ahorrar tiempo y cjastos Esta lista incluye ocurrencias comunes q...

Page 15: ...10 2 cm para cjuiar el cable blindado de la cubierta a la caja de conexiones Approx 3 208 240V caja de empalme para ia estufa ei_ctrica Los paneies de relleno iateraJes dei gabinete son necesarios para aislar la unidad de los gabinetes adyacentes La aitura dei relleno lateral dei gabinete debe permitir la instaiaci6n de modelos de tapas de cocina aprobados 36 Min 91 4 cm Min Carte minima hasta que...

Page 16: ...Nofas 16 ...