Summary of Contents for 79049283000

Page 1: ...76 cm Built in Oven Installation 90 7 Kg H 11 7 8 30 2 CAUTION Install two 3 7 6 cm wide x 3 4 1 9 cm thick planks _ capable of supporting 200 Ibs __ _ space between the bottom of the warmer drawer cutout and the bottom of the oven cutout This is a critical dimension and must be provided J_ 3 7 6 cm Max Electrical Junction Box for wall oven must be lower than warmer drawer cutout A HEIGHT B WIDTH ...

Page 2: ...es or CSA C22 1 Part I in Canada and local code requirements Tools You Will Need Phillips Screwdriver Pencil Ruler or Tape Measure and Straight edge Hand Saw or Saber Saw Spirit Level Figure I 2 Slide drawer into cutout opening until front frame of drawer is flush against cabinet Be careful not to pinch electrical cord 3 Remove the drawer as instructed in the Use Care Guide and secure drawer housi...

Page 3: ...the receptacle is properly grounded Where a standard 2 prong wall receptacle is installed it is the personal responsibility and obligation of the consumer to have it replaced by a properly grounded 3 prong wall receptacle Do not under any circumstances cut or remove the third ground prong from the power cord Disconnect electrical supply cord from wall receptacle before servicing cooktop Preferred ...

Page 4: ......

Page 5: ...CHO_ARGO DE LA ABERTURA I LA ABERTURA 251 2 64 8 cm 23 5 8 60cm 253 65 4 cm 24 61 cm 28_ 2 72 4 cm 23 5 8 60cm 283 73 cm 24 61 cm IMPORTANTE El caj6n calentador funciona con un suministro de energia el_ctrica de corriente alterna de tres cables de una sola fase de 120 voltios 60 hertz con Ifnea a tierra Instalaci6n de la combinaci6n caj6n calentador y homo de 30 76 cm integrado Precauci6n Dos tabt...

Page 6: ... de c6dlgos locales Herramlentas que usted neceslta Destornillador de estrella Phillips L6piz Regla o cinta rnedidora y recjla recta Serrucho manual o serrucho de sable Nivel de burbuja 2 Deslice el caj6n hacia dentro de la abertura de la abertura hasta que el marco frontal del caj6n est6 a ras contra el gabinete Tencja cuidado de no pinchar el cable el_ctrico 3 Removerel caj6n como indica el manu...

Page 7: ...l_ctricos desde el artefacto Un electricista calificado debe verificar el enchufe de pared y el circuito para asegurar que el enchufe est6 conectado a tierra correctamente En caso de encontrarse con un enchufe de pared de dos paras es la personal responsabilidad y la obligaci6n del consumidor reemplazado por el enchufe de pared a fierra de tres paras correspondiente No debe bajo nlnguna clrcunstan...

Page 8: ......

Page 9: ... Combin_ tiroir r_chaud four encastr_ de 30 76 cm ATTENTION Deux pianches de 3 7 6 cm de large X 3 _ 9 cm d _pais doivent 6tre instalt_es et elles doJvent 6tre en mesure de _ supporter un poids de 200 Ibs 90 7 Kg 74 9 cm _ _ a_ _ _ G H 11 7 8 30 2 cm Min est I espace _ requis entre le bas de I ouverture du tiroir r_chaud et le bas de I ouverture du four Cette dimension est critique et dolt _tre re...

Page 10: ...ips Crayon R_gle ou ruban 6 rnesurer et 6querre Scie b main ou scie sauteuse Niveau 6 bulle 2 Glissez le tiroir dans I ouverture du d6coupage jusqu b ce que son cadre avant soit tout contre I arrnoire Veillez b ne pas coincer le cordon 61ectrique 3 Retirez le tiroir tel qu expliqu6 darts le manuel d utilisation et d entretien et fixez le chassis du tiroir b I arrnoire b I aide des 3 vis plaqu6es a...

Page 11: ...seill6 de faire v6rifier la prise de courant murale et le circuit par un 61ectricien qualifi_ afin de s assurer que la prise de courant est correctement mise 6 la terre Darts le cas ob il n y a qu une prise de courant murale bipolaire standard il incombe au client de la remplacer par une prise de courant murale tripolaire correctement mise la terre U est strlctemenf interdlt de couper ou d enlever...

Page 12: ...12 ...