14
Gas connection
All connections must be wrench-tightened
Flare
Union
Flare
Union
GAS FLOW
Manual
Shutoff
Valve
Closed
Open
Flexible
Connector
Inlet Pipe on
Back of Dryer
e
l
p
p
i
N
Shutoff Valve -
Open position
to dr
yer
from gas supply
1
Remove the shipping cap from gas pipe at the rear
of the dryer.
4
Check for gas system leaks with a manometer. If a
manometer is not available, test all connections by
brushing on a soapy water solution.
3
Open the shuto
ff
valve in the gas supply line to
allow gas to
fl
ow through the pipe. Wait a few
minutes for gas to move through the gas line.
2
Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or
approved pipe from gas supply line to the 3/8 inch
(0.96 cm) pipe located on the back of the dryer. Use
a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer
for the connection. Apply an approved thread sealer
that is resistant to the corrosive action of lique
fi
ed
gases on all pipe connections.
WARNING
EXPLOSION HAZARD
NEVER test for gas leaks with an open
fl
ame.
IMPORTANT
The supply line must be equipped with an approved
manual shuto
ff
valve. This valve should be located in the
same room as the dryer and should be in a location that
allows ease of opening and closing. Do not block access
to the gas shuto
ff
valve.
IMPORTANT
DO NOT connect the dryer to L.P. gas service without
converting the gas valve. An L.P. conversion kit must be
installed by a quali
fi
ed gas technician.
Installation Instructions