9
Clearance requirements
Manufactured or mobile home installation
1
Installation MUST conform to current Manufactured
Home Construction & Safety Standard, Title 24
CFR, Part 32-80 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD
Part 280) or Standard CAN/CSAZ240 MH.
2
Dryer MUST be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting that
will not support combustion. Metal ducting must be
4 inches (10.2 cm) in diameter with no obstructions.
Rigid metal duct is preferred.
3
If dryer is exhausted through the
fl
oor and area
beneath the mobile home is enclosed, the exhaust
system MUST terminate outside the enclosure with
the termination securely fastened to the mobile
home structure.
4
Refer to previous sections in this guide for other
important exhaust venting system requirements.
5
When installing a gas dryer into a mobile home, a
provision must be made for outside make up air. This
provision is to be not less than twice the area of the
dryer exhaust outlet.
6
Installer MUST anchor this (1) dryer or (2) dryer
mounted on pedestal to the
fl
oor with approved
Mobile Home Installation Kit - P/N 137067200.
WARNING
EXPLOSION HAZARD
Do not install the dryer where gasoline or other
fl
ammables are kept or stored. If the dryer is installed
in a garage, it must be a minimum of 18 inches (45.7
cm) above the
fl
oor. Failure to do so can result in death,
explosion,
fi
re or burns.
IMPORTANT
DO NOT INSTALL YOUR DRYER:
1
In an area exposed to dripping water or outside
weather conditions.
2
In an area where it will come in contact with
curtains, drapes, or anything that will obstruct the
fl
ow of combustion and ventilation air.
3
On carpet. Floor MUST be solid with a maximum
slope of 1 inch (2.5 cm).
Installation Requirements