4. Remove the washer and put the new one in place.
5. Screw the handle and cap assembly back into the drain valve
and retighten using a wrench. DO NOT OVER TIGHTEN.
6. Follow instructions in the
Filling The Water Heater
section.
7. Check for leaks.
8. Follow the lighting instructions in the
Lighting
section to restart
the water heater.
FIGURE 25.
Service
Before calling for repair service, read the
Start Up Conditions
and
Operational Conditions
found in the
Troubleshooting Guide
of this manual.
If a condition persists or you are uncertain about the operation of
the water heater, let the Sears Service Center check it out.
Contact Sears Service Center at:
1-800-4-MY-HOME
®
(1-800-469-4663).
2. CLOSE the cold water inlet valve to the water heater.
3. OPEN a nearby hot water faucet and leave open to allow
for
draining.
4. Connect a hose to the drain valve and terminate to an
adequate drain.
5. OPEN the water heater drain valve to allow for tank
draining.
NOTE: If the water heater is going to be shut down and
drained for an extended period, the drain valve should be
left open with hose connected allowing water to terminate
to an adequate drain.
6. Close the drain valve.
7. Follow instructions in the
Filling The Water heater
section.
8. Follow the lighting instructions in the
Lighting
section to restart
the water heater.
Drain Valve Washer Replacement
(See Figure 25)
1. Turn “OFF” gas supply to water heater.
2. Follow “Draining” instructions.
3. Turning counter clockwise (
), remove the hex cap below
the screw handle.