Summary of Contents for KENMORE 758.144151

Page 1: ...5 Model No 758 144151 FOR YOUR SAFETY R EAD ALL INSTRUCTIONS CAREFULLY QUIETCOMFORT WHOLE HOUSE HUMIDIFIER 13 Gallon Output Innovative Twin Fan Technology Operating Instructions Parts List I _J Sears Roebuck and Co Hoffman Estates IL 60179 U S A Part NO SP6327 Printed in Canada ...

Page 2: ...rd or damage to humidifier do not tilt jolt or tip humidifier while unit is running 8 To reduce the risk of damage to humidi fier unplug humidifier when water bot tles are empty or when the humidifier is not in use 9 To reduce the risk of accidental electri cal shock do not touch the cord or con trols with wet hands t0 Note the warning label shown below WARNING To reduce risk of fire elec I tric s...

Page 3: ...cription Gallon Output 24 Hrs Capacity of Bottles Sq Ft Coverage Fan Speeds Filters Fill Light Desired Humidity Light Automatic Humidistat Controls CUL Listed AHAM Certified Volts Hertz Amps Watts 42 14415 13 2 3 8 Gallons Each 2700 3 4 Yes Yes Yes Rotary Yes Yes 120 A C 60 2 88 165 Based on an area with average insulation and an 8 foot ceiling height ...

Page 4: ...l surface in an area of house where most humidity is need ed or one which would likely result in moist air being circulated throughout the house such as near a cold air return Placing the unit level is very important if the humidifier is located on carpeting NOTE The 13 gallon humidifier contains water bottles The weight of the bottles in the front of the cabinet may cause the front Humidified Air...

Page 5: ...s humidifier has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse plug If it still does not fit contact a qualified Water Fill WARNING To reduce the risk of shock I always unplug humidifier before clean I ing or servicing I WARNING To reduce the risk of fire or shock hazard do not pour or s...

Page 6: ...ible leaks by performing the following 1 Grasp bottle handle and hold the bottle upright over a sink 2 Press up on valve cap plunger for about one second to let out a little water 3 Release the plunger 4 Listen for air bubbles Look for leaks around the E Z Fill Side Cap 5 If you hear air bubbles or see leaks retighten the E Z Fill Side Cap and repeat steps 1 4 Wipe off excess water from the bottle...

Page 7: ...ected humidity level is met the fans will shut off and the green Desired Humidity light will illuminate When more humidity is called for the fans will turn on and theI_t will go out Speed Control The unit is adjusted from OFF to 3 with a rotary speed control The higher the air flow speed the more water is evaporated and released into the air Low speed 1 is the quietest and is provided for conditio...

Page 8: ...ps running and the Desired Humidity indicator is illuminated the humidity level is at the normal require ments for that setting or it is adjusting to the home conditions The chart below shows recommended indoor humidity lev els The figure below shows approximate relative humidity percentages which corre spond to the various settings of the Humidity Control Recommended When Outdoor Indoor Relative ...

Page 9: ...floor coverings are not suscepti ble to water damage i e kitchen or bath areas 2 Open the pivoting lid and remove water bottles and set aside Grasp the fan assembly front center and rear center Lift off and set aside on a clean fiat sur face The fitter housings are now acces sible Pivoting Lid 3 Lift fiifer housing out of cabinet and place where you may work on them comfort ably With a soft absorb...

Page 10: ...f the top covers are positioned towards the center of the cabinet Fixed Tabs Spring Tabs _J Humidifier Be sure that the spring tabs of filter housings are towards front of cabi net Align the lower portion of the filter assembly over the six ribs located at the boilom rear of the humidifier cab inet Top indents Cover Towards Center of Cabinet f Position fan assembly onto the cabi net Make sure the ...

Page 11: ...oved Step 2 To Remove Parts a Open the pivoting lid and remove water bottles and set aside Grasp the fan assembly front center and rear center Lift off and set aside on a clean flat sur face The filter housings are now accessible b Before removing the internal pads of the humidifier cabinet we recommend moving the humidifier to an area where floor coverings are not susceptible to water damage i e ...

Page 12: ...nd of humidification season 2 Remove and throw away filters 3 Let humidifier dry completely before storing Do not store with water inside cabinet or water bottles 4 Store in cool dry location 5 Install a new filters in clean humidifier before next season begins 6 Bi Weekly is also recommended if you do not plan to rue the humidifier for one week or more Disinfecting Humidifier Cabinet and Water Bo...

Page 13: ...resh new filters 42 14911 Bottle cap plunger missing Check orientationof bottles post in bottom of cabinet RepesitJonso that bottle cap plunger stem is depressed by post in bottom of cabinet Left bottle not emptying Right bottle contains water The humidifier is designed so the right bottle empties first Continue to run until fill light comes on Right bottle not emptying Wrong valve assembly cap En...

Page 14: ...24 23 28 27 ...

Page 15: ...ludes KeyNo s15 1E Standard Hardware Item May be purchased locally Key Pad No Description No 18 509229 1 19 828199 1 20 823726 21 STD601107 22 828515 23 823849 24 42 14911 25 828197 26 828534 27 828115 1 28 822406 1 30 828196 31 824120 32 826367 33 STD610603 SP6327 Cap Valve Assembly Cabinet Rail Kick Screw Pan Hd Ty AB 10 x 3 4 Caster Twin Wheel Support Filter Lower 1 Filter Evaporative Support U...

Page 16: ...22 For information on purchasinga Sears MaintenanceAgreementor to inquire about an existingAgreement Call 9 am 5 pm Monday Saturday 1 800 827 6655 SEARS 4r_eijca S V ep_r Sp_c_IIStS 1he model numberwill be foundonthe Humidifier identilication label When requestingservice or ordering pads always providethe following information ProductType Model Number Part Number Part Description 2000 Emerson Elec...

Reviews: