12
Determine vent length and elbows needed for best drying
performance:
■
Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE:
Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those specified
will:
■
Shorten life of dryer.
■
Reduce performance, resulting in longer drying times
and increased energy usage.
Kenmore Vent System Chart
Number of
90° elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The Vent System Charts provides venting requirements that will
help achieve best drying performance.
NOTE:
Bottom exhaust installations have a 90° turn inside the
dryer. To determine maximum exhaust length, add one 90° turn to
the charts.
Determine vent path:
■
Select route that will provide straightest and most direct
path outdoors.
■
Plan installation to use fewest number of elbows and turns.
■
When using elbows or making turns, allow as much room
as possible.
■
Bend vent gradually to avoid kinking.
■
Use as few 90° turns as possible.
B
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.
A
B
A. Over-the-top installation
(also available with one offset elbow)
B. Periscope installation
A
B
A. Standard rear offset exhaust installation
B. Bottom exhaust installation
NOTE:
The following kits for close clearance alternate installations
are available for purchase. Contact your local dealer.
■
Over-the-Top Installation:
Part Number 4396028
■
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29" (737 mm)
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)
mismatch
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
Moblie Home Exhaust installation
Summary of Contents for W10562379A
Page 2: ...2 DRYER SAFETY ...
Page 3: ...3 IMPORTANT When discarding or storing your old clothes dryer remove the door ...
Page 18: ...18 SEGURIDAD DE LA SECADORA ...
Page 19: ...19 IMPORTANTE Cuando descarte o guarde su vieja secadora de ropa quítele la puerta ...
Page 36: ...36 ...
Page 51: ...NOTES ...