14
3
3
/
4
"
(95 mm)
11"
(279 mm)
Attach long hose to dryer fill valve
and tighten coupling
5.
Attach other end of long hose
to fill valve at bottom of dryer
back panel. Screw on coupling
by hand until it is seated on fill
valve connector. Using pliers, tighten
the couplings an additional two-
thirds turn.
NOTE:
Do not overtighten. Damage
to the coupling can result.
Turn on cold water faucet
6.
Check that the water faucets are turned on.
Check for leaks
7.
Check for leaks around “Y” connector, faucets, and hoses.
CONNECT VENT
1.
Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is clean.
Dryer vent must fit over dryer exhaust outlet and inside exhaust
hood. Check that vent is secured to exhaust hood with a 4" (102
mm) clamp.
Move dryer to final location
2.
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove cardboard from under dryer.