This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices other than
normal residential housekeeping purposes.

When using an electrical appliance, basic precautions should always be followed, including the following:

Read all instructions before using.

WARNING!

To reduce the risk of fire, electric shock, or injury:
Failure to follow these safety instructions could result in damage to the machine, damage to property, or bodily injury.

Use machine only as described in this manual. Do not use in ways it was not intended. Use only manufacturer’s recommended
attachments.

Do not leave the machine unattended when it is plugged in. Turn off all switches and unplug the electrical cord when not in use
and before servicing.

Do not allow to be used by untrained personnel. Close attention is necessary when used near children.

If the machine is not working as it should, has been dropped, damaged, or left outdoors, return it to a service center before using.

Avoid electrical shock, do not handle the plug or machine with wet hands. To unplug the cord, grasp the plug. Do not pull on the
cord.

Do not use extension cords or outlets with inadequate current carrying capacity. Do not use with a damaged cord or plug. Connect
the machine only to a properly grounded outlet (refer to GROUNDING INSTRUCTIONS). Avoid damaging cord (closing doors
on cord, pulling around sharp edges or corners, hot surfaces, or running machine over cord).

This machine creates suction. Keep hair, loose clothing, fingers, and all other parts of the body away from openings and moving
parts. Do not insert any object into any of the openings in the machine.

Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.

Do not use the machine to pick up flammable or combustible liquids such as gasoline. Do not use in areas where flammable and/
or explosive vapor or dust is present to avoid the possibility of fire or explosion. Some cleaning fluids can produce such vapors.

Do not allow water or foam to overflow and enter the vacuum tube on the recovery tank. If this happens, immediately shut off
the vacuum motor, unplug the machine.  Contact an authorized service center.

SAVE THESE INSTRUCTIONS

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for 56648033

Page 1: ...7 00 Form Number 56041494 083471M 1 OPERATOR MANUAL Kent MODELS 56648033 56648035 SelecTrac 17T 17THP h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Page 2: ...1494 SelecTrac 17T 17THP FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Page 3: ... shock do not handle the plug or machine with wet hands To unplug the cord grasp the plug Do not pull on the cord Donotuseextensioncordsoroutletswithinadequatecurrentcarryingcapacity Donotusewithadamagedcordorplug Connect the machine only to a properly grounded outlet refer to GROUNDING INSTRUCTIONS Avoid damaging cord closing doors on cord pulling around sharp edges or corners hot surfaces or run...

Page 4: ... del cordón No use cordones de alargamiento o tomacorrientes con una capacidad de corriente inadecuada No la use con un cordón o un enchufe dañado Conecte la máquina solamente a un tomacorrientes bien conectado a tierra consulte las INSTRUCCIONES DE PUESTA A TIERRA Trate de no dañar el cordón cerrando puertas y dejando el cordón aprisionado tirando contra bordes puntiagudos o esquinas superficies ...

Page 5: ... m long PLEASE NOTE FOR NORTH AMERICA ONLY 120VAC INTRUCCIONES PARA HACER LA TOMA A TIERRA Este aparato deberá ser conectado a tierra En caso de malfuncionamiento o de desperfectos la toma a tierra proporciona una vía de menor resistencia de la corriente eléctrica para reducir el riesgo de choques eléctricos Esta unidad viene equipada con un cordón con conductores para toma a tierra y con un enchu...

Page 6: ...ladder CAUTION Solution temperature must not exceed 170 F 76 C Use non foaming chemicals or defoamer and be sure to use the correct dilution ratios PUMP PRIMING FIGURE 6 KX 17THP Model only Prime the pump system by connecting the drain hose whichisthe4footlongsolutionhosewithaconnectionononeend tothequick disconnect at the back of the machine and place the open end of the hose in the solution tank...

Page 7: ... Attach the drain elbow on the drain valve Place a pail under the down spout and pull up the drain valve T handle Dirty solution will pour out until the bladder is empty Close the drain valve Use a clean bucket when you refill the solution tank EMPTYING THE SOLUTION TANK FIGURE 12 For model KX 17T place a bucket under the drain valve Remove the recovery bladder fork slide the bladder off the seal ...

Page 8: ...spray spray is weak or uneven from nozzle Clogged nozzle coupler or solution filter screen Debris inside pump or plumbing Punctuered pump diaphram 100 PSI pump only Defective or clogged pump check valve 100 PSI pump only Worn pump bearing this makes excessive noise Cracked pump housing Defective rectifier or motor Lost pump prime 300 PSI pump Pressure regulator set incorrectly 300 PSI pump only Va...

Page 9: ...ymouth MN 55447 3408 www nilfisk advance com Phone 800 989 2235 Fax 800 989 6566 2000 Nilfisk Advance Inc Plymouth MN 55447 3408 Printed in the U S A h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0 ...

Reviews: