SYMPTOM
POSSIBLE CAUSE
SOLUTION
No power to the machine.
1. Building circuit breaker tripped.
1. Unplug any other equipment on the
same circuit. Wait five minutes, reset
circuit.
Note:
If breaker continues to
trip, try outlets on another circuit. If new
circuit continues to trip, DO NOT use
the unit. All motors and wires must be
examined for defect.
2. Defective wall outlet.
2. Plug machine into different outlet.
Also:
Check if outlet is wired to a light
switch.
3. Defective
Plug.
3. Replace
Plug (10109).
4. Loose Power Connection.
4. Check
Lever Nuts (10267 / 10277)
to
black and white wires.
5. Defective
Power Cord.
5. Replace
Power Cord (18205).
Power is intermittent to all or some of
the motors.
1. Loose
Terminal
or
Lever Nut.
1. Replace loose
Terminals
or
reconnect
Lever Nut.
2. Burned or corroded
Terminals.
2. Replace
Terminals.
3. Defective
Switch.
3. Replace
Switch (10308/18032).
4. Defective
Wire
or
Power Cord.
4. Replace
Wire
or
Power Cord (18205).
Electrical short.
1. Damaged or loose wire connection
that touches any metal on the machine.
1. Check for damaged or loose wires
and make sure all ground wires are
properly connected.
2. Defective motor touching improperly
grounded metal on the machine.
2. Replace defective motor and make
sure all ground wires are properly
connected.
3.
Wire
,
Power Cord
or
Terminal
with
worn insulation.
3. Replace
Wire, Power Cord
or
Terminal
.
7
Summary of Contents for C4-100A
Page 1: ...Maintenance Repair Manual Models C4 100A C4100LM C4 UPBLMDeepCleaningExtractors ...
Page 2: ...7001 ...
Page 20: ...Models C4 100A C4100LM C4 UPBLM Parts List and Diagrams ...
Page 21: ...18 ...
Page 23: ...20 ...
Page 25: ...22 ...
Page 27: ...24 ...
Page 29: ...26 ...
Page 30: ...27 ...
Page 31: ...28 ...
Page 32: ...29 ...
Page 35: ...32 ...
Page 37: ...34 ...
Page 39: ...36 ...
Page 41: ...38 ...
Page 42: ...39 ...