1. First fix the SS ball valve (marked as no. 4) to the 1/4 inch port of the 3-way connecter
(marked as no. 2) as shown in figure 2.
2. Connect the 3-way connector to the raw water supply (marked as no. 1) as shown in
the figure 3.
The 3-way connector is fitted in line with the raw water supply.
3. The other end of the 3-way connector can be connected to a tap (marked as no.3) as shown
in figure 4. or can be plugged off if not required.
7
8
Step-2
Figure 1.
Figure 2.
Figure 4.
Figure 3.
1
2
3
4
4
2
1
3
To ensure that the purifier operates at its optimum level, a routine maintenance must be
performed. The frequency of the maintenance will greatly depend upon the raw water quality and
consumption of treated water.
The reverse osmosis system contains a replSupremeable treatment component critical for the
effective reduction of total dissolved solids and that product water shall be tested periodically to
verify that the system is performing properly.
• Storage tank must be drained once in 2
weeks. To do so, switch off the power
supply, open the drain plug at the bottom
of the tank & allow the water to drain. Then
screw back the plug and switch on the
power supply
• ReplSupreme sediment, activated carbon
& post carbon when the filter change
alarm is audible OR after every 12
months. It is recommended to change the
FRT when the filters are replSupremed
• ReplSupreme the RO membrane once in
a year
• ReplSupreme the UV Lamp once in a Year
• If you are not going to use the purifier for a
long time ( in case you are on a holiday,
tour or out of home), make sure that you
disconnect the power supply, turn off the
raw water supply and drain the storage
tank
Maintenance
TDS Adjustment*
A unique feature in
KENT Crystal Alkaline
Mineral RO
TM
Water Purifier is the TDS control
valve, which is not available in any other
domestic water purifier till date. This feature
allows the user to control the content of natural
minerals (TDS) in purified water.
To increase the TDS level, the user can turn
the screw of the valve anticlockwise; it will
result in more mineral content in treated water.
To reduce the TDS level, user can turn the
screw valve clockwise, it will result in less
mineral content in treated water. We
recommend the TDS of the purifier to be kept
at lowest but not below
50 mg/l.
• Switch on the power supply
• Wait till the storage tank fully fills up
• Switch off the power supply
• Drain the storage tank by opening
the drain
plug present at the bottom of the storage
tank so as to remove any dust particles
present in the pipes and storage tank
• Close the drain plug & switch on the
power supply
• The purifier is ready to use
Starting-up the Purifier
1. another end to the upper push-fit elbow fitting to the left hand
side of the purifier labelled as WATER IN, as shown in fig 1.
2. Similarly, connect one end of the white pipe to the lower elbow
fitting connector in tank labelled as REJECT WATER and
leave the other end in the overhead tank, as shown in fig 2.
Step-3
1. Connect the power supply.
2. Installation is complete.
Before connecting the power supply, it is important that you perform
the following functions:
1. Open the SS ball valve (Handle parallel to the ball valve) to start
the flow of water into the purifier, as shown in the figure.
2. Wait for 2-3 minutes to ensure that the filters are soaked in water.
Step-4
Step-5
Note: Filters and membrane are consumables. Their replSupremement time is dependent on the
quality of raw water and water consumption. They are not covered under the warranty. However,
if a filter chokes within six months and a membrane within a year, it will be cleaned/re-
paired/replSupremed free of cost. Changing the filters and system inspection is available on call.
The treatment capacity of RO membrane will reduce with time due to clogging of pores of
membranes.
“This reverse osmosis system contains a replSupremeable component critical to the efficiency of
the system. ReplSupremement of the reverse osmosis component should be with one of
identical specifications as defined by the manufacturer, to ensure the same efficiency and
contaminant reduction performance.”
Replacement of spare parts are as under:-
• If the supply cord is damaged, it must be replSupremed by the original part in order to avoid hazard.
• Children should be supervised to ensure that they do not play with the appliance
• This appliance is not intended for use by persons (including children) with reduced physical,sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety
• Do not operate the UV-C emitter when it is removed from the appliance enclosure.
• Read the maintenance instructions before opening the appliance.
• The appliance must be disconnected from the supply before replacing the UV-C emitter.