background image

Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of 
raw  water  and  water  consumption.  They  are  not  covered  under  the  warranty.  However,  if  a  filter 
chokes within six months and a membrane within a year, it will be cleaned/repaired/replaced free of 
cost. Changing the filters and system inspection is available on call. The treatment capacity of RO 
membrane will reduce with time  due  to  clogging  of  pores  of  membranes.
“This reverse osmosis system  contains  a replaceable  component critical to the  efficiency  of the 
system.  Replacement  of  the  reverse  osmosis  component  should  be  with  one  of  identical 
specifications  as  defined  by  the  manufacturer,  to  ensure  the  same  efficiency  and  contaminant 
reduction performance.”

The reverse osmosis system contains a replaceable treatment component critical for the effective 
reduction of total dissolved solids and that product water shall be tested periodically to verify that the 
system is performing properly.

Replacement of spare parts are as under:-

To  ensure  that  the  purifier  operates  at  its 

carbon  when  the  filter  change  alarm  is 

optimum level, a routine maintenance must be 

audible  OR  after  every  12  months.  It  is 

performed. The frequency of the maintenance 

recommended to change the FRT when the 

will greatly depend upon the raw water quality 

filters are replaced

and consumption  of  treated  water.

Replace the RO membrane once in a year

Storage  tank  must  be  drained  once  in  2 

Replace  the  UV  Lamp  once  in  a  year

weeks. To do so, switch off the power supply, 

If you are not going to use the purifier for a 

open the drain plug at the bottom of the tank 

long time ( in case you are on a holiday, tour 

& allow the water to drain. Then screw back 

or  out  of  home),  make  sure  that  you 

the plug and switch  on  the  power  supply

disconnect the power supply, turn off the raw 

Replace sediment, activated carbon & post 

water supply and drain  the  storage  tank

n

n

n

n

n

Maintenance

8

-20008

SP   Inline Sediment Filter  10"

-20009

SP   Inline Carbon Filter  8"

-20001

SP   RO Membrane Welded  10" Housing

-20015

SP   Post Carbon Filter (Blue)

-20003

SP   Hollow Fibre Membrane (RO)

-20018

SP FRT 550

7

n

n

n

n

n

n

Switch on the power supply

so as to remove any dust particles present in 
the  pipes  and  storage  tank

Wait till the  storage  tank  fully  fills  up**

Close  the  drain  plug  &  switch  on  the  power 

Switch off the power supply

supply

Drain  the  storage  tank  by  opening  the  drain 
plug present at the bottom of the storage tank 

The purifier is ready to use

Starting  Up  the  Purifier

5.

6.

7.

(I)

(ii)

Now connect one end of the white pipe to the SS ball valve and other 
end  to  the  lower  pushfit  elbow  fitting  on  the  left  hand  side  of  the 
purifier labeled as WATER IN.  (Note :  White  pipe  is  for  raw  water  
supply)

Similarly, connect one end of the blue pipe to the upper elbow fitting 
connector labeled as REJECT WATER  and  leave  the  other  end  in  
the  drain. (Note :  Blue  pipe  is  for  reject  water)

Before connecting the power supply, it is important that you perform 
the following functions:

Open  the  SS  ball  valve  (Handle  parallel  to  the  ball  valve)
to start the flow of water into  the  purifier.

Wait for 2-3 minutes to ensure that the filters are soaked in water.

TM

screw of the valve anticlockwise; it will result in 

A unique feature in 

Grand

Mineral RO  

more mineral content in treated water. To reduce 

Water Purifier is the TDS control valve, which is 

the  TDS  level,  user  can  turn  the  screw  valve 

not available in any other domestic water purifier 

clockwise, it will result in less mineral content in 

till date. This feature allows the user to control the 

treated  water.  We  recommend  the  TDS  of  the 

content of   natural   minerals   (TDS) in   purified   

purifier to be  kept  at  lowest  but  not  below  50 

water 

mg/l.

To increase the TDS level, the user can turn the 

KENT

 

TDS  Adjustment*

Although  the  rejected  water  has  high 

concentration  of  salts  and  minerals  which 

concentration  of  salts.  This  rejected  water 

accelerate  plant  growth.  Rejected  water  can 

usually goes down the drain but if required, can 

also be used for cleaning purposes, i.e. utensils  

be  used  for  gardening  purposes.  It  has  high 

cleaning,  mopping, etc.

Recommended  Uses  of  Rejected Water

* Tested & Certified by TUV-SUD South Asia (P) Ltd.
** Tested or certified flushing time - 24hrs.

Summary of Contents for Grand+ Mineral RO

Page 1: ...NO 199716 Manufactured by A 2 Sector 59 Noida U P 201 309 India Ph 91 120 3075075 E mail sales kent co in Website www kent co in KENT RO SYSTEMS LTD TM Mineral RO 2005 2012 KENT RO SYSTEMS LTD the pr...

Page 2: ...ree service To ensure that the warranty of your water purifier is effective it is important that you fill up the enclosed warranty card and mail us the installation report within 15 days of purchase I...

Page 3: ...sure that the purifier is connected to cold water supplyonly Do not try to service the purifier on your own Instead call service technician for help To keep the storage tank clean it should be drained...

Page 4: ...stream of waste water and thus do not get accumulated as in a traditional filter UV Process The UV light has shorter wavelength higher energy than the visible light It is called ultra violet because i...

Page 5: ...urifier are switched off Purification Delay To ensure that the idle water lying in the internal pipes and in the UV chamber is disinfected before being passed into the storage tank the system provides...

Page 6: ...1 SP RO Membrane Welded 10 Housing 20015 SP Post Carbon Filter Blue 20003 SP Hollow Fibre Membrane RO 20018 SP FRT 550 7 n n n n n n Switch on the power supply so as to remove any dust particles prese...

Page 7: ...emove from drinking water than pentavalent arsenic Trivalent arsenic can be converted to pentavalent arsenic in the presence of an effective oxidant such as free chlorine The arsenic in water containi...

Reviews: