R AD AR
23
3.4
3.5
Level adjustment
After installing the base, put two level gauges at the edge of table as T-shaped(as ).
Adjust level adjusting block under the table(as ), use wrench to adjust(as ).
Turn clockwise to increase height, and turn counterclockwise to decrease height, until the
level gauges reach to the level status. At this moment, level gauge is centered on the
table center to rotate 90 degree, then to adjust it again. Continuous adjust it until the table
reaches level status.
After installing column, Z-axis, and tool magazine, use diameter to measure Z-axis(as ),
to move Z-axis up and down, make sure Z-axis is vertical to the table. If Z-axis is not.
If Z-axis is not vertical to the table, adjust 3 level adjusting blocks behind (as ).
After adjusting column, check the level of table. If not reach to the level status,
adjust adjusting level blocks below the table (as ), until the table reaches level status
and Z-axis is vertical to the table.
1
2
4
3
5
4
1
2
3
4
1
2
3
4
NO:
Model:
Title:
Page:
KENT INDUSTRIAL USA,
INC.
1
3
2
4
5
A
C
D
B
A
C
D
B
Level adjustment
R121090901F
KVTC-120
1 / 1
3.
Installation
3.
Installation
3.
Installation
3.
Installation
3.
Installation
3.
Installation
Property
of
Kent
Industrial
USA
Do
Not
Reproduce