R AD AR
70
tightly. Although the piping system is not leakage, it may occur that the air
The best way to avoid inhalation of air is to connect hydraulic system pipes
to be inhaled into the oil. The main reason is due to the bad connection for oil
high-speed through the return pipe.
pipe. But it also may be happened when the oil flows back to oil tank in
before operating hydraulic system. The air must be possible to remove in
In order to obtain precise positioning of valve, it needs to remove the air
compression. If the air remains in the oil, it will make noise and vibration as
the hydraulic oil, to avoid oil and air mixed together resulting in different
10 kg/cm² (smaller value), and set flowing at the minimum value. Start the
the valve acting. The method of removing air is to set the system pressure to
driving device and repeat the action several times. The air will be removed
completely.
c.