R AD AR
87
The sliding surface of X / Z axis cannot be lubricated:
(1)
To check the quantity of lubricant, if the oil is not reduced, the pump must have a
problem. Should check or replace the pump.
Pipes or valves may be blocked; all circuits should be clean until return to normal.
The cooling motor is not running. Check the breaker of pump motor is overloaded
or not. If motor failure, should be repaired or replaced.
Check the motor running direction, pay attention to wiring and the motor running in
the right direction.
Check the inlet filter of coolant, make sure it's clean.
When the coolant level is low, add coolants to sufficient amount.
Cannot adjust the hydraulic pressure unit:
As hydraulic motors are unable to run, regardless of overload or not,
If the pump or motor is failure, should repair or replace it.
Check the running direction of hydraulic motor, pay attention on wiring.
Check the hydraulic suction filter, make sure it's clean.
Check the inlet and outlet of hydraulic pump have leaking or not, leaks will cause
pressure down.
When the oil level is low, add oil to sufficient amount.
When the hydraulic pump worn and damaged, please contact maker for repairing or
replacement, to avoid the uncertainty occurred.
a.
b.
Coolant does not flow out:
(2)
a.
b.
c.
d.
a.
b.
c.
d.
e.
f.
(3)
check the breakers of pump motor circuit.
7.3 Troubleshooting for others
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
7.
Troubleshooting
Property
of
Kent
Industrial
USA
Do
Not
Reproduce