background image

Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of  raw water 
and water consumption. They are not covered under the warranty. However, if  a filter chokes within six months and a 
membrane  within  a  year,  it  will  be  cleaned/repaired/replaced  free  of   cost.  Changing  the  filters  and  system 
inspection is available on call. The treatment capacity of  RO membrane will reduce with time  due  to  clogging  of   
pores  of   membranes.

“This reverse osmosis system contains a replaceable component critical to the efficiency of  the systems. 
Replacement of  the reverse osmosis component should be with one of  identical specifications as defined by 
the manufacturer, to ensure the same efficiency and contaminant reduction performance.”

The reverse osmosis system contains a replaceable treatment component critical for the effective reduction of  
total dissolved solids and that product water shall be tested periodically to verify that the system is performing 
properly.

Replacement of  spare parts are as under:-

Maintenance

-20010

SP   Inline Sediment Filter  8”

-20009

SP   Inline Carbon Filter  8”

-20529

SP   RO Membrane HF

-20015

SP   Post Carbon Filter (Blue)

-20003

SP   Hollow Fibre Membrane (RO)

-20020 

SP   FRT 300

carbon when the filter change alarm is audible OR 

To ensure that the purifier operates at its optimum level, 
a  routine  maintenance  must  be  performed.  The 

after  every  12  months.  It  is  recommended  to 

frequency of  the maintenance will greatly depend upon 

change the FRT when the filters are replaced

the  raw  water  quality  and  consumption    of     treated   
water

Replace the RO membrane once in a  year

Storage tank must be drained once in 2 weeks. To 

Replace the UV Lamp once in a year

do so, switch off  the power supply, open the drain 

If  you are not going to use the purifier for a long 

plug at the bottom of  the tank & allow the water to 

time ( in case you are on a holiday, tour or out of  

drain. Then screw back the plug and switch   on   

home), make sure that you disconnect the power 

the  power  supply

supply, turn off  the raw water supply and drain  the  
storage  tank

Replace  sediment,  activated  carbon  &  post 

n

n

n

n

n

n

n

n

n

n

n

Switch on the power supply

as  to  remove  any  dust  particles  present  in  the   
pipes  and  storage  tank

Wait till the  storage  tank  fully  fills  up**

Close the drain plug & switch on the power supply

Switch off  the power supply

The purifier is ready to use

Drain  the  storage  tank  by  opening  the  drain 
plug present at the bottom of  the storage tank so 

Starting-up  the  Purifier

TDS  Adjustment*

* Tested & certified by TUV-SUD South Asia (P) Ltd.
** Tested or certified flushing time - 24hrs.

We  recommend  keeping  the TDS  at  lowest  but  not  below  50mg/l. 

n

n

Turning the screw of  the valve clockwise, results 

in a decreased mineral content.

Turning  the  screw  of   the  valve  anti-clockwise, 

results in an increased mineral content.

The  unique TDS  Control  System  enables  customers  to  retain  the  contents  of   natural  minerals  (TDS)  in 

purified water, as per their requirement.

10

9

Summary of Contents for Prime Mineral RO

Page 1: ...us at www kent co in Marketed by E 6 7 8 Sector 59 Noida U P 201 309 India Ph 91 120 3075000 E mail sales kent co in Website www kent co in KENT RO SYSTEMS LTD M LnK_KENT_2017_BOX MANUALS Manuals Prime manual_with_ISI New Size 5 5 8 25 dt 005 05 17 job no 1697 Kent Deta Hai Sabse Shudh Paani System Tested and Certified by WQA to NSF ANSI 58 for the reduction of Barium Fluoride Lead Nitrate Nitrite...

Page 2: ...ree service To ensure that the warranty of your water purifier is effective it is important that you fill up the enclosed warranty card and mail us the installation report within 15 days of purchase In case you need any further information contact your nearest dealer branch Best Wishes KENT KENT KENT KENT RO SYSTEMS LTD Table of Contents 1 1 2 Salient Features 1 3 Items in the Box 1 4 Important In...

Page 3: ...ter Municipal Corporation Water Supply Double treatment by RO UV processes controlled operations for enhanced purity and long life RO water recovery 50 Filter Change Alarm to indicate filter High Purification efficiency of 20 L hr replacement time Inbuilt auto flushing system UV FailAlarm to indicate failure in UV system Membrane with high flow RO Membrane fused inside membrane Inbuilt TDS Control...

Page 4: ...es reduction of particles as small as ions from a solution Reverse Osmosis uses a semi permeable membrane to reduce salts from potable brackish water In Reverse Osmosis water pressure applied to the concentrated side forces the process of osmosis into reverse Under enough pressure treated water is squeezed through the membrane from the concentrated side to the diluted side Salts dissolved in water...

Page 5: ...ade without prior written approval for products clogged by suspended matter precipitates or biological growth or for failures resulting from the lack of proper maintenance 10 KENT Purifiers or its ASP cannot and shall not be held liable for any sickness or illness due to the consumption of drinking water from any water purifier supplied by KENT Purifiers since KENT Purifiers or its ASP does not ha...

Page 6: ...Installation Date Service Provider s Name Service Provider s Address Service Provider s Ph TDS of Raw Water By signing on this installation report the customer hereby agrees to the terms conditions of warranty mentioned on the back side of the warranty card Customer s Signature Service Provider s Stamp 4 Water Flow Diagram Electrical Circuit Diagram HF ...

Page 7: ...h off the purifier and call the service technician for help The purifier will stop its purification process in such a circumstance 2 Sec 2 Sec 2 Sec 2 Sec Filter Change Alarm KENT TM Prime Mineral RO has an in built feature that sounds an audible alarm to indicate replacement time for filters This alarm will be audible after 700 hrs of use since the last filter change or since the time of installa...

Page 8: ...ker on the wall preferably at 3 6 to 4 feet from the ground or as per convenience Step 02 Ensure that the sticker is pasted straight on the wall Drill holes as per the markings provided on the sticker Step 03 Using a hammer insert the puff up in the wall Step 04 Screw two 10 x 50 sized self taping screws 5 5 inches 140 mm apart horizontally Step 05 Install the tank on wall using screws Step 06 Con...

Page 9: ...12 months It is recommended to frequency of the maintenance will greatly depend upon change the FRT when the filters are replaced the raw water quality and consumption of treated water Replace the RO membrane once in a year Storage tank must be drained once in 2 weeks To Replace the UV Lamp once in a year do so switch off the power supply open the drain If you are not going to use the purifier for...

Page 10: ...n be converted to pentavalent arsenic in the presence of an effective oxidant such as free chlorine The arsenic in water containing detectable free chlorine or that has been treated with another effective oxidant will be in the pentavalent arsenic form 4Treatment with chloramine combined chlorine is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic Consumers ...

Reviews: