background image

Installation  Procedure  :

Screw in the two 10x50 self taping screws (supplied with the package) on a same horizontal level at  
a  distance  of  5.4 inches (138 mm)  from  each  other  in  the  wall.

Carefully hang the purifier on the wall with the help of wall mounting slot 
holes present on the back side of the purifier as shown in the figure below.

Fix the SS ball valve to the ¼ inch port of the 3-way connector as shown in the figure.

1.

2.

3.

4.

Connect the 3-way connector to the raw water supply as shown in the 
figure. The threaded end of the 3-way connector is fitted in line with the 
raw water supply. The other end can be connected to a tap or can be 
plugged  off  if  not  required.

TM

The 

 Prime

 TC 

Mineral RO

 

Water Purifier is a product of advanced technology, which ensures safe  

and  clean  drinking  water.  The  purifier  is  easy and  convenient  to  install.

Recommended  Site  Preparations :

100-300 V~, 50-60Hz single phase AC connection not more than 3m away from the point of installation 
of purifier
Raw water supply with ½” nipple not more than 3m away
Drain for rejected water not more than 3m away
Space as per dimensions of the purifier
Wall/plane surface for mounting two screws and holding the machine

The system and installation must comply with state and local laws and regulations

Specific Instructions :

TM

Prime TC 

Mineral RO  Water Purifier is a wall mountable purifier. Make sure that it is only 

mounted on a wall.  Avoid  installation  on  wooden  and  metallic  stands
For optimum performance and minimum inlet pressure required, ensure that the raw water supply 
tank  is  at  least  10 ft  above  the  level  at  which  the  purifier  is  installed
It  is  preferable  to  install  the  purifier  near  a  sink  so  that  inlet  and  reject  water  lines  are  easily 
available

KENT

KENT 

n

n

n

n

n

n

n

n

n

Installation  Instructions

6

Slot holes

5

UV  Fail  Alarm

To ensure delivery of 100% pure and healthy water, a micro-processor is installed in the purifier that 
performs  the  following  functions: -
UV Stabilization Delay: To ensure that the UV lamp is pre-heated and is working at its optimum level 
before it starts disinfecting water, the controller provides a two seconds delay to UV lamp when the 
purifier  is  switched  on.  During  this  period,  only  the  UV  lamp  is  switched  on  and  other  electrical 
devices  of  the  purifier  are  switched  off.
Purification Delay: To ensure that the idle water lying in the internal pipes and in the UV chamber is 
disinfected before being passed into the storage tank, the system provides 5 second delay when the 
purifier is switched on.  During this time, the UV lamp kills all micro-organisms that may be in the water 
inside UV chamber. After this delay, all other electrical devices such as booster pump and solenoid 
valve  are  switched  on  to  start  normal  purification  process.
Audible Alarm: The controller also controls the timing of UV Fail Alarm and the Filter Change Alarm.

Computer  Controlled  Operation

n

n

n

n

The purifier automatically shuts off when the   

The  purifier  automatically  restarts  when 

storage  tank  becomes  full

water  level  drops  below  the  maximum

The  purifier  does  not  start  when  inlet  water   

The purifier does not allow any water rejection in 

2

supply  pressure  is  below  0.3 kg/cm

absence  of  electricity / when  tank  is  full

Automatic  Operation

KENT 

TM

Prime

 TC Mineral RO  Water Purifier has an in-built feature that sounds an audible alarm if the UV 

lamp malfunctions. This  feature  is  provided  to  ensure  100%  purity.  This  UV  Fail  Alarm  will  sound  
like  following:
Two short beeps after every two seconds.

In case such an alarm is audible, kindly switch off the purifier and call the service technician for help. The  
purifier  will  stop  its  purification  process  in  such  a  circumstance.

2  Sec.

2  Sec.

2  Sec.

2  Sec.

Filter  Change  Alarm

KENT 

Prime TC Mineral RO has an in-built feature that sounds an audible alarm to indicate replacement 

time for filters.  This alarm will be audible after 700 hrs of use since the last filter change (or since the time 
of installation). The  Filter  Change  Alarm  will  sound  like  following:
4 short beeps after every two seconds; for 30 seconds. The alarm will repeat after every 2 hours of use.

In case such an alarm is audible, please call the service technician and request him to change the filters of 
the purifier.  However, if the filters are not changed within the next 60 hours of operation, the purifier will  
stop  functioning  to  ensure  purity  and  hygiene.  The  following  alarm  will  be  audible  after  60  Hrs.  
A continuous beep for an infinite time.

In case, such an alarm is audible, kindly switch off the purifier and call the service technician to replace 
the  filters.  In  such  a  circumstance,  the  purifier  will  not  function  unless  the  filters  are  changed.

2  Hours

30  Sec.

30  Sec.

Summary of Contents for PRIME TC

Page 1: ...kee District Haridwar Uttarakhand 247 668 India KENT RO SYSTEMS LTD ISO 9001 2008 C e r t i f i e d GOLD MEMBER Instruction Handbook for Installation Operation and Maintenance Kent Deta Hai System Tes...

Page 2: ...ok forward to years of trouble free service To ensure that the warranty of your water purifier is effective it is important that you fill up the enclosed warranty card and mail us the installation rep...

Page 3: ...off function New eye appealing design Computer controlled operations for ABS construction for corrosion free use enhanced purity and long life TM Salient Features of KENT Prime TC Mineral RO Water Pu...

Page 4: ...al filter UV Process The UV light has shorter wavelength higher energy than the visible light It is called ultra violet because it is just beyond violet light in the light spectrum Technically the ult...

Page 5: ...shall not be held liable for repair or alterations made without prior written approval for products clogged by suspended matter precipitates or biological growth or for failures resulting from the la...

Page 6: ...te Installation Date Service Provider s Name Service Provider s Address Service Provider s Ph TDS of Raw Water By signing on this installation report the customer hereby agrees to the terms conditions...

Page 7: ...ctrical devices of the purifier are switched off Purification Delay To ensure that the idle water lying in the internal pipes and in the UV chamber is disinfected before being passed into the storage...

Page 8: ...pipe is for reject water Before connecting the power supply it is important that you perform the following functions Open the SS ball valve Handle parallel to the ball valve to start the flow of wate...

Page 9: ...Weight Storage Capacity Purification Production Rate Maximum Duty Cycle Membrane Type Booster Pump Voltage Power Consumption Input Power Supply 11030 Suitable for Purification of Brackish Tap Water Up...

Reviews: