Thank you for your decision to buy a KENTIX monitoring solution based on the KENTIX MultiSensor 
technology.

Features

The Kentix MultiSensor-LAN is an All-in-One system unit with many integrated sensors.
The MultiSensor-LAN can be a stand-alone device or operated in conjunction with a Kentix AlarmManager. 
By the use with an AlarmManager provides you a more extensive functionality.
The MultiSensor-LAN is installed in server room or rack. It controls and forwards all alarm and fault 
messages to the responsible persons.
The configuration is done with the integrated web server, comfortable with a web browser. 
For the connection and installation of the devices you can choose from two options:

Plug and Play 

installation with plug technology - without wiring and jamming. Voltage supply by 

„Power over Ethernet“ (PoE).

Fixed installation

 with conventional installation cables.

Applications

• Industry and Trade
• Banks
• Authorities and hospitals
• Telecommunications
• Law firms and medical practices
• Energy and water utility

Safety note

The installation of the MultiSensors must be run by an competent person.

In a power failure, the settings are not lost. Energized relays drop out and go back when the power returns in 
the unswitched output state.
To bridge longer downtime, use a suitable UPS system.

Installation

To ensure the security and integrity of the operator, and the correct operation of the KENTIX MultiSensor-
LAN, the execution of the installation only has to be done by an expert. There must also the relevant 
requirements are met.

Environment

The installation must be such that the KENTIX MultiSensor-LAN and all associated cables are not affected 
by, environmental conditions: 

dust, humidity, excessive heat, direct sunlight, heat sources, devices 

that build strong electromagnetic fields, liquids or corrosive chemicals.

See the technical data sheet for more technical data and environment conditions.

  

Protection

During the installation of the alarm manager, certain degrees of protection must be guaranteed. Observe the 

relevant regulations for installation in certain environments such as industrial or residential and commercial 

buildings.

Page 3                                          

!

(09-2012, subject to change)

!

www.kentix.de

Summary of Contents for MultiSensor-LAN

Page 1: ...User Manual MultiSensor LAN From Firmware Version 2 xx xx...

Page 2: ...ation Network 6 2 6 Configuration Sensors and Alarm 7 2 7 User accounts and notification 8 2 8 Language 8 2 9 Software update MultiSensor LAN 9 2 10 Copy or save Configuration of MultiSensor LAN 9 2 1...

Page 3: ...actices Energy and water utility Safety note The installation of the MultiSensors must be run by an competent person In a power failure the settings are not lost Energized relays drop out and go back...

Page 4: ...t to the power supply over PoE power over ethernet So you can operate the device without another power supply direct by an PoE capable switch The market standard PoE injectors can also be used for pow...

Page 5: ...hot or exceeded NOK There is a measurement undershot or exceeded an alarm is triggered ON Function or input output status is switched on OFF Function or input output status is switched off Monitoring...

Page 6: ...larmManager and set the hook FTP server activation The integrated FTP server can be activated or deactivated The FTP access will be needed for a software update of the device Look up in the chapter so...

Page 7: ...he CO content The measurement is construed to the highest sensitivity and can be changed slightly in the adjustment Carbon Monoxide concentrations like they emerge in fires are detected even at 100 se...

Page 8: ...me when a triggered alarm shall be triggered The alarm will be sent to the entered e mail addresses until all values are in normal range again A value of 0 sets the alarm repeating to inactive User ac...

Page 9: ...ate file will be deleted from the filesystem of the MultiSensor IMPORTANT During the update procedure the power supply must not break 7 Now the MultiSensor is accessible and you can see the software v...

Page 10: ...minutes Current data http MultiSensorIP xml values xml Historical data http MultiSensorIP xml record xml Switch alarm output 2 In the category system you can find a way to turn on the alarm output 2...

Page 11: ...nsor there where is also the config ini file After a reboot the configured command sequence will send to the camera in case of an alarm Up to five cameras can be controlled create for each camera a ne...

Page 12: ...The alarm inputs of the device are only on System connector 1 of the terminal connection of the KIO1 adapter available Page 12 09 2012 subject to change www kentix de IMPORTANT The switching outputs 6...

Page 13: ...port side forward 3 Pull the lid at the sides apart sightly see picture 4 The lid will snap out from the surrounding groove with a clicking noise 5 Now you can pull up the lid Close the device lid 1 L...

Page 14: ...RM red RUN yellow LINK ACT at the LAN jack LAN 10 100 Mbit LAN connection integrated web server SNMP Simple Network Management Protocol SNMP V2 write read SNMP Traps XML Output Actual and historical v...

Page 15: ...facturers websites Copyright Notice All rights reserved Any text images graphics animations and videos as well as content and structure of this manual are protected by copyright and other laws protect...

Reviews: