background image

KTR-140

Shenzhen Kentro Medical Electronics Co.,Ltd   

2nd Floor, No. 11, Shanzhuang Road, Xikeng Village, 

Yuanshan Street, Longgang District, Shenzhen City, 

Guangdon Province, China

[Tel]: +86(755)33825998, [Fax]: +86(755)33825996

Summary of Contents for KTR-140

Page 1: ...140 Shenzhen Kentro Medical Electronics Co Ltd 2nd Floor No 11 Shanzhuang Road Xikeng Village Yuanshan Street Longgang District Shenzhen City Guangdon Province China Tel 86 755 33825998 Fax 86 755 33825996 ...

Page 2: ...ou can get more value added enjoyment Product Features Designed according to ergonomics beautiful and scientific in line with the neck curve Low frequency electric pulse magnetic effect hot compress and circular traction four in one synchronized health care form a composite energy field Hot compress using three levels of low temperature medium temperature and high temperature you can choose accord...

Page 3: ...n battery CR2032 front positive upward Put it in the battery compartment of the remote control insert the positioning pin on the top of the battery cover first and then press the battery cover tightly 2 Function operation 1 Wet the cervical spine and the conductive sheet with a wet towel and then put the massager close to the neck If there is sweat on the cervical spine it must be cleaned before u...

Page 4: ...f 4 Key using Pulse mode switching button you can select six pulse modes by pressing the remote control button and the default setting is mode 1 automatic combination 1 mode when power on The intensity is the first gear after each mode change The six massage modes are Mode 1 Automatic combination 1 Mode 2 Automatic combination 2 Mode 3 Scratch Mode 4 Press Mode 5 Roll Mode 6 Beat The automatic com...

Page 5: ...ars 30 minutes per day 4 When the rechargeable battery is not used for a long time the service life of the rechargeable battery will be shortened It is recommended to fully charge it at least once a month 1 The built in lithium battery of this product contains substances that may pollute the environment Before disposing of this product the built in lithium battery should be removed 2 Before disass...

Page 6: ...d Symbols The symbol means prohibition things not permitted The specific contents of such prohibitions are shown behind or near this symbol with words or illustrations The symbol on the left means Dis assembly Prohibited The symbol means compulsive requirements things that must be obeyed The specific contents of such compulsive requirements are shown behind or near this symbol with words or illust...

Page 7: ...o conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that maycause undesired operation Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Warning NOTE This equipment has been tested and found to comply...

Page 8: ...table time for treatment is 15 20 minutes Check whether the patient is massaged in a high intensity Properly reduce the intensity Check whether the patient s skin is sensitive to electrodes Check if the patient s skin had any allergies in the past if any slight allergy please shorten the massage time and if any serious allergy please stop using this apparatus immediately and then offer desensitiza...

Reviews: