Start the vehicle, Check for leaks
Commercial Diesel Engines
1.
For most Large Diesel Engines use one of the following adapters DFS-910-2,
DFS-910-3, DFS-910-4 and attach DFS 910-5 to one of these adapters.
2.
Attach Blue and Black hoses to DFS 910-5.
3.
Set air Pressure on Atomizer Tank to 80 psi Start Engine.
4.
Open air valve on DFS 910-5 adapter then turn the Atomizer valve to ON position
on the machine run until Atomizer fluid tank is empty.
5.
Turn Atomizer valve of and Fill the Atomizer Tank with 1 lit/qt Rinse Solution
and repeat the above steps.
6.
Turn Atomizer Valve to OFF position. Turn Vehicle off, turn fuel pump off on the
machine then disconnect fuel hoses, adapters and reattach the EGR temperature
sensor, boost pressure sensor, reconnect fuel lines and reattach induction parts.
DFS 910-2
DFS 910-3
DFS 910-5
DFS 910-4