46
FEEDER CABLE SECTION
Type “H05RR-F”
230 V ac
3 x 1,5 mm
2
CONNECTION OF THE POWER SUPPLY CABLE
•
Unhook the terminal board cover by inserting a screwdriver into the two hooks “
A
” (fig.
10.1).
•
Open the cable gland by unscrewing screw “
F”
(fig. 10.2), unscrew the terminal screws.
•
Insert the feeder cable of the suitable section (as described in the next chapter) into
the cable gland.
•
Connect the phase, neutral and earth cables to the terminal block according to the
diagram in figure 10.3.
•
Pull the feeder cable and block it with cable gland.
•
Close the terminal block cover (check the two hooks “
A
” are correctly hooked).
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
F
A
230 V
E
N
L
E Earth
N
Neutral
L
Live
Fig. 10.3
Fig. 10.2