DV-5050M/5900M/DVF-J6050/J6050-G
27
ADJUSTMENT
No.
DVF-J6050
E version
ITEM
INPUT
SETTING
OUTPUT SETTING
ALIGNMENT
POINT
ALIGNMENT
FOR
FIG.
1
Y LEVEL
100% COLOR
BAR DISC
Connect the oscilloscope to
composite(X13,J4) with
75-ohms resistor
VR301(X35)
VR304(X35)
VR600(X25)
Y-signal =
1000mV
±
30mV
FIG.1.
2
CHROM LEVEL
100% COLOR
BAR DISC
PAL DISC
(PAL MODE)
Connect the oscilloscope to
composite(X13,J4) with 75-
ohms resistor
Chrom-signal =
300mV
±
15mV
FIG.2.
3
YCb Cr LEVEL
(DVF-J6050 only)
100% COLOR
BAR DISC
Connect the oscilloscope to
Y output(X13,J6) with
75-ohms resistor
Y-signal =
1000mV
±
30mV
FIG.1.
•
•
1000mV
±
30mV
Y
4.7
µ
s
-300
0
700(100IRE)
[mV]
white
Fig. 1
yellow
cyan
green
magenta
red
blue
black
700
623
490
413
287
210
77
0
Sync. chip
IRE
Peak white
Blank
0
Fig. 2