26
✓
The power supply cord must not touch against any hot surfaces and must be placed so
that its temperature does not exceed 75°C at any point along its length.
✓
After having installed the appliance, the power switch or power plug must always be in a
accessible position.
✓
The appliance must have its own supply; any other appliances installed near it must be
supplied separately.
✓
N.B. For connections to the mains power supply, never use adaptors, reductions or multi-
ple power points as these may overheat and catch fire.
✓
In the event that installation should require modifications to the mains supply wiring sys-
tem or if the power plug is not suitable for the type of power point available, it is recom-
mended that a qualified technician be called to carry out substitution. The technician will
also have to verify that the cross-section of the electric cables on the power point match
the appliance’s power rating.
✓
If the supply cord is damaged, it must be replaced by a special cord by a qualified electri-
cal technician in order to avoid a hazard.
GENERAL NOTES
✓
The wires in the mains lead on this appliance are coloured in accordance with the fol-
lowing code:
Green and Yellow - Earth
Blue – Neutral
Brown – Live
✓
As the colours may not correspond with the markings identifying the terminals in your
plug or in your spur box, proceed as follows:
➜
The green and yellow wire must be connected to the terminal which is marked with
the letter E or with the earth symbol
or coloured green and yellow.
➜
The blue wire must be connected to the terminal marked N or coloured black.
➜
The brown wire must be connected to the terminal marked L or coloured red.
FEEDER SPECIAL CABLE SECTION - Type “HO5V2V2-F”
resistance to temperatures of 90°C
230 VAC 50 Hz 3 x 0,75 mm
2
✓
The supply cable must be replaced with a cable of
the same type.
✓
The electrical cable must be connected to the
terminal board following the diagrams of Fig. 6.3.
230 V
L1
N(L
2
)
PE
Fig. 6.3