AC
E
BD
2
1
3
5
7
4
6
KD-291R/291RC
Y21-3250-10
DC voltages are as measured with a high impedance
voltmeter at 33-1/3 r.p.m. mode. Values may vary
slightly due to variations between individual instru
-
ments or/and units.
CAUTION:
For continued safety, replace safety critical components
only with manufacturer's recommended parts (refer to parts list).
indicates safety critical components. To reduce the risk of electric
shock, leakage-current or resistance measurements shall be carried
out (exposed parts are acceptably insulated from the supply circuit)
before the appliance is returned to the customer.
MOTOR ASS'Y (KH-JM0221M6)
D101
D102
D101
D104
D103
IN4148
AN6652
MM16S2
-RWH
R101
270
1
2
4
3
IC 1
M
B
A
C102
10u
16
C101
1000u
16
SW2
POWER PCB ASS'Y
IN4001x4
PT 101
AC 120V
60Hz
(K,P) TYPE
CARTRIDGE
GND LINE
+ B LINE
(X,T,E) TYPE
R 101
R 102
300
300
300
300
VR 1
VR 2
33RPM
45RPM
SW1
Y TYPE
SW1
OFF : 33 rpm
ON : 45 rpm
M TYPE
T 200mA 250V
T 200mA 250V
T 200mA 250V
AC 220V
SW3
AC 110V
AC 110-120V /
220-240V
50/ 60Hz
AC 110-120V /
220-240V
50/ 60Hz
SW3
AC110V
AC220V
X,T : 240V / 50Hz
E : 220V / 50Hz
T • F
T• F
+
+