11
KDC-MP202/MP333
KDC-MP333RC/MP433
●
Other
• When started in Test Mode, duration of prohibiting LINE
MUTE shall be changed from 10 seconds to 1 second.
• When in Test Mode, when DC offset error detection is run,
the detection information is not written into the E2PROM.
●
Special displays while all lights are on
When all lights are on with STANDBY source, if the follow-
ing keys are pressed, the following messages are displayed.
[1] key
Version is displayed (forwarding)
(Display) TYPE : x_ _ _ (“x” is displayed in hexadecimals)
→
558K – 2.05 (“development ID” – “version”)
→
all lights on
→
∗
TYPE indicates
µ
-com destination, and shows real-time
condition of the destination terminal.
[2] key
All lights ON.
[3] key
Key pressed: Power ON time is displayed.
While Power ON time is displayed, press and hold for 2
seconds or longer to clear the Power ON time.
(Display)
PON_0Hxx (00~50 is displayed for “xx”)
xxxxx (00001~10922 is displayed for “xxxxx”)
MAX 10922 (hours)
[4] key
Key pressed: CD operation time is displayed.
Press the key for more than 2 seconds while the CD
operation time is displayed to clear CD operation time.
(Display)
CDT_0Hxx (00~50 is displayed for “xx”)
xxxxx (00001~10922 is displayed for “xxxxx”)
MAX 10922 (hours)
[5] key
Key pressed: Number of CD EJECT time is displayed.
While the CD EJECT times is displayed, press and hold
for 2 seconds or longer to clear the CD EJECT time.
(Display) EJCxxxxx
MAX 65535 (times)
[6] key
Key pressed: Number of times PANEL is opened/closed
is displayed.
Press the key for more than 2 seconds while the PANEL
open/close count is displayed to clear the PANEL open/
close count.
(Display) PC_xxxxx
MAX 65535 (times)
[FM]
ROM correction version is displayed
key
(Display) ROM_R123
ROM_R – – – (When not written in)
ROM_R
∗ ∗ ∗
(When data not matching)
[AM]
IC10 adjustment status
key
“E2P_OK”: Adjustment completed
“E2P_ER” : E2PROM values are still default (not determined)
“I2C_ER” : Communication not possible between IC10
and E2PROM.
∗
If “E2P_OK”, Pin 60 (TUN FANC OUT) should be
output as “H”.
[
]
AUDIO data initialization
key
(Display) AUD_INIT
[
]
Key pressed: Forced Power OFF data displayed.
key
While the forced power OFF data is displayed, press and
hold for 2 seconds or longer to clear the data.
(Display) POFF_ – – – (No Forced Power OFF)
PNL (Forced Power OFF because of
system
µ
-com panel communication error)
[
]
Key pressed: CD information display mode ON/OFF
key
While in CD information display mode, press and hold for
2 seconds or longer to clear all CD information.
∗
Please refer to the next table.
CD information display mode
I2C communication condition display
(Display) I2C_OK_ _
NG
[AM]
CD mechanism error log display
key
(switched by [
] / [
] keys)
↑
(Display) MCERR1_: x x
↔
MCERR2_: x x
↔
MCERR3_: x x
↔
MCERR1_: x x
↔
(“– –” or the error code is displayed for “xx”)
CD loading error log display (switched by [
] / [
] keys)
(Display) LDERR1_: x x
↔
LDERR2_: x x
↔
LDERR1_: x x
↔
(Number of times is displayed for “xxx”)
CD ejection error log display (switched by [
] / [
] keys)
(Display) EJERR1_: x x
↔
EJERR2_: x x
↔
EJERR3_: x x
↔
EJERR4_: x x
↔
EJERR1_: x x
↔
(Number of times is displayed for “xxx”)
CD time code error count data display (missing counts)
(switched by [
] / [
] keys)
(Display) CNT_LOSE
↔
CDDA_xxx
↔
CDROMxxx
↔
CNT_LOSE
↔
↓
(Number of times is displayed for “xxx”)
[FM]
CD time code error count data display (count not updated)
key
(switched by [
] / [
] keys)
(Display) CNT_STAY
↔
CDDA_xxx
↔
CDROMxxx
↔
CNT_STAY
↔
(Number of times is displayed for “xxx”)
TEST MODE