13
KDC-MP202/MP333
KDC-MP333RC/MP433
ADJUSTMENT
1. IC10 (X34-) -The Tuner adjustment method
• When IC10 and its circumference are repaired, according
to the following order, it readjusts if needed.
• The adjustment item changes with parts to exchange. Please
refer to "Parts vs Adjustment item table".
1-1. VCO coil adjustment - adjustment of tunning voltage
Voltage Check Point
: Vt-Check Land
(PWB Side B, around D506)
Adjustment Coil
: L507 (VCO Coil)
The adjustment method : VCO coil is turned and adjusted
according to the following tables.
Type
Mode
freq.
Voltage
Fig.
E/M
AM
1611kHz
5.5
±
0.1(V)
2, 3 (C)
K
AM
1700kHz
5.8
±
0.1(V)
2, 3 (C)
J
FM
90.0MHz
5.6
±
0.1(V)
2, 3 (C)
M : AM Adjustment
For Your Information : The frequency of this unit is only set
up by preset key in case this adjustment
1-2. Adjustment of 1st & 2nd-MIX coil
Voltage Check Point
: S-METER-Check Land
(PWB Side B, around R216)
Adjustment Coil
: 1st IFT=L508 / 2nd IFT=L509
Setting of Signal Generator : Refer to the following tables
Type
Mode
freq.
Mod.
ANT Input
Fig.
K
AM
1000kHz
OFF
35dB
µ
EMF
1~3 (B),(C)
E/M/J
AM
999kHz
OFF
35dB
µ
EMF
1~3 (B),(C)
q
The appearance and the coil with which S-METER DC volt-
age serves as the maximum are turned and adjusted in the
above-mentioned SG input.
w
By the above-mentioned adjustment method, same adjust-
ment is performed to both sides (1st & 2nd MIX Coil).
1-3. Adjustment of FM ANT & RF coil
Voltage Check Point
: S-METER-Check Land
(PWB Side B, around R216)
Adjustment Coil
: ANT Coil = L505
RF Coil = L506
Setting of Signal Generator : Refer to the following tables
Type Mode
freq.
Mod.
ANT Input
Fig.
E/M
FM
87.5MHz
OFF 5dB
µ
V or 11dB
µ
EMF 1~3 (A),(C)
K
FM
87.9MHz
OFF 5dB
µ
V or 11dB
µ
EMF 1~3 (A),(C)
J
FM
76.0MHz
OFF 5dB
µ
V or 11dB
µ
EMF 1~3 (A),(C)
q
The appearance and the coil with which S-METER DC volt-
age serves as the maximum are turned and adjusted in the
above-mentioned SG input.
w
By the above-mentioned adjustment method, same adjust-
ment is performed to both sides (ANT & RF Coil).
1-4. Adjustment of STEREO (adjustment of 456k-VCO)
Adjust in TEST MODE
• How to enter the test mode
Refer to “TEST MODE”.
• Adjustment method
While in test mode and all lights are lit (STANDBY), press
and hold [1] key and press [6] key for 3 seconds or longer.
(Adjusted data will be written on E2PROM.)
Effect of adjustment is in cofirmation of adjustment status
at Preset [AM] key.
• Display of Preset [AM]
Adjustment OK: “E2P OK” (14-segment display model)
Adjustment NG: “E2P ERR” (14-segment display model)
• How to clear the test mode
Refer to “TEST MODE”.
[Fig.3]
(UNDER VIEW)
[Fig.2]
[Fig.1]
(OVER VIEW)
(REAR VIEW)
(TUNER ANT)
(A)
(B)
S-METER
Check Land
IC10
Vt
Check Land
FM-SG
AM-SG
(C) DC Voltmeter
L509
L508
L507
L506
L505