KDC-X879
15
●
Menu-related specifications
• A short press of the Q key initiates the menu mode.
• Pressing the DNPP key on the remote initiates the Menu
mode.
• Continuous holding of a remote control key is inhibited, and
workings are short press of any keys.
• Contrast is adjusted in 3 steps of 0 / 5 / 10 with the Track
Up/Down keys (Default value at 5).
●
Backup current measurement
When the unit is reset while ACC is OFF (i.e. by turning
Backup ON), the MUTE terminal goes OFF in 2 seconds in
place of 15 second. (The CD mechanism is not activated at
this time.)
●
Special display when the display is all on
Pressing the Preset keys while the power is ALL OFF dis-
plays the following information.
[PRESET 1]
Version display (8 digits, Month/Day/Hour/Minute)
(Display) SYS xxxxxxxx :
PAN xxxxxxxx : FL model only
MEM xxxxxxxx : 4 contrasts FL model only
[PRESET 2]
Serial number display (8 digits)
(Display) SNo xxxxxxxx
[PRESET 3]
Short press : View power ON time. (The All OFF
period is not counted.)
2 seconds long press/hold : Clear power ON time
at the power ON time displaying.
(Display) PonTim xxxxx
Max. 60000 (hours)
[PRESET 4]
Short press : Display CD operation time.
2 seconds long press/hold : Clear CD operation
time at the CD operation time displaying.
(Display) CDTim xxxxx
Max. 60000 (hours)
[PRESET 5]
Short press : Display CD ejection count.
2 seconds long press/hold : Clear CD ejection
count at the CD ejection count displaying.
(Display) EjeCnt xxxxx
Max. 60000 (times)
[PRESET 6]
Short press : Display Panel open/close count.
2 seconds long press/hold : Clear Panel open/close
count at the Panel open/close count.
(Display) PnCnt xxxxxx
Max. 600000 (times)
FM key
Display ROM collection version.
(Display) ROM R xxx
Invalid : “R – – –”
AM key
Display panel E2PROM condition.
(Display) P–ROM OK (Registered code)
P–ROM NG (Code is write in error)
P–ROM WAIT (Unregistered code)
P-ROM NON (Panel security nonfunctional)
●
Panel mechanism
• Auto-panel close inhibition when set-in the CD.
• The panel operation inhibition at power ON/OFF and ACC
ON/OFF.
• The panel position changing Eject
→
Last with a short press
of the PLAY/PAUSE keys.
●
Other specifications
• No displays such as “CODE OFF/ON” during Power-ON.
• The LINE MUTE inhibition time is one second from 10 sec-
onds when start-up the test mode.
• Do not write the security code with the security jig on the
test mode.
• Do not write the serial with the serial writing jig on the test
mode.
• OEM display output is not stop if OEM display not connec-
tion on the test mode.
●
Switching the frequency span (K/M type)
While holding the Preset 1 key and Preset 5 key, reset the
unit.
●
Demonstration mode
1. How to enter to the Demonstration mode
1. Hold down the [Q] key and [TI (AME)] key button when the
power is on and press the Reset button.
2. This will enter to the Demonstration mode.
2. How to chancel the Demonstration mode
1. Hold-down the Preset [5] key button when the power is on
and press the Reset button.
2. This will cancel the Demonstration mode.
TEST MODE