KMD-PS971R/X92
6
TEST MODE
(1) How to enter the test mode
1. Reset the unit while holding the "FM" and preset "6" keys depressed.
2. All indications light up at the moment when the test mode starts.
(2) How to cancel from the test mode
1. Reset the unit while holding the preset "6" key.
(Note) The test mode is not canceled by turning ACC OFF, turning power OFF or causing momentary power
down.
(3) FM S-meter voltage adjustment
1. Enter the test mode.
2. While holding the preset "1" key depressed, press and hold the preset "6" key.
3. "ADJ OK" is displayed when the result is OK or "ADJ NG" is displayed when it is No Good.
(4) AM SD voltage writing
1. Enter the test mode.
2. While holding the preset "1" key depressed, press and hold the preset "6" key to write the SD voltage data.
(5) Forced Auto / Manual switching of K2I
1. Press and hold the TI key in the tuner mode to switch between AUTO and MANUAL.
2. The initial status is MANUAL, which is indicated by the lighting of the TI dots.
(6) Forced Narrow/Wide switching of K2I
1. Press the preset "6" key in the tuner mode to switch between Forced Narrow and Wide.
2. The initial status is Wide, which is indicated by the lighting of the NEWS dots.
(7) MD test mode
1. Track jumps to the following tracks in order from left by track-up key pressed.
No.7, No.2, No.13, No.23, No.30, No.34, No.7(Returns to the start position).
2. Track down key will be one step down than currntly playing track No.
3. When pressing preset "1" key, the track jumps to track No.28. When pressing preset "1" key again, the track
jumps to track No.22.
(8) Audio adjustments
1. The volume should be set to -10 dB (displayed as "30").
2. The bass/treble and balance/fader controls are set to full boost/full cut and full front/full rear respectively by sin-
gle press of the UP/DOWN key.
3. The high-pass filter is set to Through/100Hz/200Hz by each press of the UP key, or to 200Hz/100Hz/Through
by each press of the DOWN key.
4. Other adjustments are identical to normal operations.
(9) Back-up current measurement
1. When the unit is reset while ACC is off (When the back-up power is on) or when ACC is turned off in the middle
of test mode, the MUTE pin turns ON in 2 seconds instead of 15 seconds. (The panel/CD/MD mechanism is
not activated at this time.)