NX-720H(G)/720H
50
ADJUSTMENT
Item
Panel test mode
PC test mode
Measurement
Adjustment
Specifi cations/
Remarks
Test-
equipment
Unit
Termi-
nal
Unit
Parts
Method
7. DQT Deviation
adjust
[Narrow]
1) Adj item:[DQT]
Adjust:[
.]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : ON
Press [
] key
to store the
adjustment value.
1) Adj item: [DQT
Deviation (Analog
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press [Transmit]
button. Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscillo-
scope
ANT
[Panel tun-
ing mode]
[
],[
]
[PC test
mode]
[
],[
]
Write the value
430
(Reference value)
0.35kHz±0.05kHz
[Wide]
1) Adj item:[DQT]
Adjust:[
.
.
.]
PTT : ON
Press
] key
to store the
adjustment value.
1) Adj item: [DQT
Deviation (Analog
Wide)]
PTT: Press [Transmit]
button. Press [Apply]
button to store the
adjustment value.
Write the value
430
(Reference value)
0.75kHz±0.05kHz
8. LTR Deviation
adjust
[Narrow]
1) Adj item:[LTR]
Adjust:[
.]
Deviation meter
LPF : 3kHz
HPF : OFF
PTT : ON
Press [
] key
to store the
adjustment value.
1) Adj item: [LTR
Deviation (Analog
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press [Transmit]
button. Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscillo-
scope
ANT
[Panel tun-
ing mode]
[
],[
]
[PC test
mode]
[
],[
]
Write the value
465
(Reference value)
0.75kHz±0.05kHz
[Wide]
1) Adj item:[LTR]
Adjust:[
.
.
.]
PTT : ON
Press [
] key
to store the
adjustment value.
1) Adj item: [LTR
Deviation (Analog
Wide)]
PTT: Press [Transmit]
button. Press [Apply]
button to store the
adjustment value.
Write the value
465
(Reference value)
1.00kHz±0.05kHz
9. DTMF Devia-
tion adjust
[Narrow]
Adj item:
[DTMF]
Adjust:[
.]
Deviation meter
LPF : 15kHz
HPF : OFF
PTT : ON
Press [
] key to
store the adjustment
value.
1) Adj item: [DTMF
Deviation (Analog
Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press [Transmit]
button. Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscillo-
scope
ANT
[Panel tun-
ing mode]
[
],[
]
[PC test
mode]
[
],[
]
Write the value
648
(Reference value)
1.5kHz±0.05kHz
[Wide]
Adj item:
[DTMF]
Adjust:[
.
.
.]
PTT : ON
Press [
] key to
store the adjustment
value.
1) Adj item: [DTMF
Deviation (Analog
Wide)]
PTT: Press [Transmit]
button. Press [Apply]
button to store the
adjustment value.
Write the value
648
(Reference value)
3.0kHz±0.05kHz
Summary of Contents for Nexedge NX-720H