NX-720H(G)/720H
55
ADJUSTMENT
Item
Panel test mode
PC test mode
Measurement
Adjustment
Specifi cations/
Remarks
Test-
equip-
ment
Unit
Terminal
Unit
Parts
Method
8. Squelch(Tight)
[Analog Narrow]
This adjustment can
be performed only
PC test mode.
1) Adj item: [Tight
Squelch (Analog
Narrow)]
2) Adj item: [Low],
[Low’], [Center],
[High’], [High]
Press [Apply All]
button to store
the adjustment
value.
SSG
ANT
Ext.SP
connector
PC test
mode]
[
],[
]
Write the value as
VHF,.
・
Analog Narrow
[S.QLT]
→
248
[S.Q.LT]
→
248
[S.Q.L.T]
→
248
[S.Q.L.T.]
→
248
[S.Q.L.T._.]
→
248
・
Analog Wide
[S.QLT]
→
255
[S.Q.LT]
→
255
[S.Q.L.T]
→
255
[S.Q.L.T.]
→
255
[S.Q.L.T._.]
→
255
[Analog Wide]
1) Adj item: [Tight
Squelch (Analog
Wide)]
2) Adj item: [Low],
[Low’], [Center],
[High’], [High]
Press [Apply All]
button to store
the adjustment
value.