NXR-901
80
ADJUSTMENT
Test Signaling
■
Analog
No.
RX (Decode Signaling)
TX (Encode Signaling)
1
None
None
2
None
100Hz Square Wave
3
QT 67.0Hz
QT 67.0Hz
4
QT 151.4Hz
QT 151.4Hz
5
QT 210.7Hz
QT 210.7Hz
6
QT 254.1Hz
QT 254.1Hz
7
DQT D023N
DQT D023N
8
DQT D754I
DQT D754I
9
None
CWID Encode (ID: VVV)
10
None
Single Tone
11
DTMF Decode (Code: 159D) DTMF Encode (Code: 159D)
12
None
DTMF Encode (Code: 9)
13
None
Courtesy Tone
■
NXDN
No.
RX (Decode Signaling)
TX (Encode Signaling)
1
RAN1
RAN1
2
RAN1
PN9
3
RAN1
Maximum deviation pattern
• Signaling number 1 is used for link test.
• Signaling number 2 is used for TX modulation signal
quality test. i.e, TX adjacent channel power, FSK error,
Occupied bandwidth, Emission mask, etc.
• Signaling number 3 is used for TX deviation test. If the
modulation mode is very narrow, the modulation fre-
quency is 600Hz. If the modulation mode is narrow, the
modulation frequency is 1200Hz.
Flat cable (36-pin) about 256mm (E37-0979-05)
Fig. 1
Center frequency: 73.05MHz
Span: 50kHz
Pass bandwidth: ±3.75kHz at 3dB
3dB max.
3.75kHz
3.75kHz
More than
25dB
12.5kHz
12.5kHz
10dB/div
Summary of Contents for NEXEDGE NXR-901