NX-420
47
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
9
. DTMF
Deviation
*
4
[Narrow]
1) Adj item: [DTMF]
Adjust:
[
.]
2) Adj item: [D.T.M.F._.]
[D.T.M.F._.](TA)
Deviation meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press
[
]key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Analog
Narrow)]
2) Adj item: [Hight],
[Hight](TA)
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
Selector
[PC test
mode]
[ ],[ ]
Write the value as
followings.
540 (Reference
value)
1.25kHz±0.05kHz
2.00kHz±0.05kHz
[Wide 4k]
1) Adj item: [DTMF]
Adjust:
[
.
.]
2) Adj item: [D.T.M.F._.]
[D.T.M.F._.](TA)
PTT: ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Analog
Wide 4k)]
2) Adj item: [Hight],
[Hight](TA)
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value
[Wide 5k]
1) Adj item: [DTMF]
Adjust:
[
.
.
.]
2) Adj item: [D.T.M.F._.]
[D.T.M.F._.](TA)
PTT: ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Analog
Wide 5k)]
2) Adj item: [Hight],
[Hight](TA)
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
2.50kHz±0.05kHz
10. MSK
Deviation
*
4
[Narrow]
1) Adj item: [MSK]
Adjust:
[
.]
2) Adj item: [M.S.K._._.]
[M.S.K._._.](TA)
Deviation meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press
[
] key to
store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Analog
Narrow)]
2) Adj item: [Hight],
[Hight](TA)
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit]
button.
Press [Apply] button
to store the adjust-
ment value.
Write the value as
followings.
513 (Reference
value)
1.50kHz±0.05kHz