1-60 (No.RA020<Rev.002>)
5.
Open
Squelch
[Analog
Wide]
1) Adj item:
[Aw SQL]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD:1kHz/±3kHz)
1) Adj item:
[Open Squelch (An-
alog Wide)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/±3kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Analog
Narrow]
1) Adj item:
[An SQL]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD:1kHz/±1.5kHz)
1) Adj item:
[Open Squelch (An-
alog Narrow)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±1.5kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[P25
(C4FM)]
1) Adj item:
[P1 SQL]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-1dB
(MOD: 1kHz/
±2.2kHz)
1) Adj item:
[Open Squelch (P25
C4FM)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -1dB
(MOD: 1kHz/
±2.2kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[P25
(LSM)]
1) Adj item:
[P1 SQL]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±3.3kHz)
1) Adj item:
[Open Squelch (P25
LSM)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/
±3.3kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
Item
Condition
Measurement
Adjustment
Specifi-
cations
/Remarks
Panel tuning mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method
Summary of Contents for NX-5700