1-78 (No.RA020<Rev.002>)
12.
Balance
*1
1) Adj item:
[Balance]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Balance]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscillo-
scope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
The Deviation of 20Hz
frequency is fixed.
Change the 2kHz ad-
justment value to be-
come the same
deviation of 20Hz within
the specified range.
(a supplementary
explanation:
Another way to adjust is
ready.
(Same as TK-5710, the
old model of NX-5700).
Press [AUX(Orange)]
key to switch the tone to
100Hz square wave.
Then, make the demod-
ulation waveform shown
on oscilloscope into
square shape.)
2kHz Tone de-
viation is with-
in ± 1.0% of
20Hz tone de-
viation.
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
*1 : Refer to the “4.19.1 Necessary Deviation adjustment item for each signaling and mode” table.
Balance adjustment is common with the adjustment of all signaling deviations.
13.
Maxi-
mum
Devia-
tion
*2
[Analog
Wide
5k]
1) Adj item: [ADEV]
Adjust:[****]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Maxmum Devia-
tion (Analog Wide
5k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
Write fixed value “491”
for each adjustment
point. (The value is writ-
ten below.) Transmit at
each adjustment point
and check that the devi-
ation is between 4150Hz
and 4250Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
4150~4250Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
Item
Condition
Measurement
Adjustment
Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method