Model name
PDS20-18
PDS36-10
PDS60-6
Rated output voltage (V)
20
36
60
Rated output current (A)
18
10
6
Output
Output voltage range (V)
0-20
0-36
0-60
Output current range (A)
0-18
0-10
0-6
Rated output power (W)
360
Constant voltage characteristics
Power regulation
0.005% +1 mV (for
10% source voltage fluctuation)
Load regulation
0.005% +2mV (for 0 to 100% fluctuation)
Ripple noise, p-p
(Measured with 20 MHz oscilloscope)
30 mVp-p
Ripple noise, rms (5 Hz – 1 MHz)
1mVrms
1 mVrms
Transient response (typ.)
100
µ
sec
Temperature coefficient (typ.)
100 ppm/
°
C
Rise time (typ.)
Full load/no 100 msec/100msec
Fall time (typ.)
Full load/no load 150msec/1000msec
Analog remote control setting accuracy
(IF 30AN optional board is used)
External voltage (+ curve) : 0 to 10V
External voltage (- curve) : 10 to 0V
External resistance (+ curve) : 0 to 10k
Ω
3%
50mV
External resistance (- curve) :10k to 0
Ω
3%
100mV
Constant current characteristics
Power regulation
5mA
1mA
Load regulation
5mA
Ripple noise, rms (5 Hz – 1MHz)
10mArms
5mArms
Temperature coefficient (typ.)
100ppm/
°
C
Analog remote control setting accuracy
(IF 30A optional board is used)
External voltage (+ curve) : 0 to 10V
External voltage (- curve) : 10 to 0V
External resistance (+ curve) : 0 to 10k
Ω
3%
50mA
External resistance (- curve) :10k to 0
Ω
3%
100mA
Meter and display
Display & accuracy
(23
5
°
C)
4 digits, LED, 0.1% rdg
2 digits
3 digits, LED,
0.1% rdg
2 digits
Voltmeter
Min. reading
10mV
100 mV
Display & accuracy
(23
5
°
C)
4 digits, LED, 0.5% rdg
2 digits
3 digits, LED,
0.5% rdg
2 digits
Ammeter
Min. reading
10mA
In constant voltage operation
CV LED is lit.
In constant current operation
CC LED is lit.
Output ON indicator
OUTPUT LED is lit.
PDS20-18/PDS36-10/PDS60-6
3
SPECIFICATIONS
PDS-20-18(K)
1,1(
98.12.3
17:07
y [ W 3