4. PRECAUTIONS FOR USE
1) Confirming the supply voltage
*Use t h i s unit w i t h i n the s p e c i f i e d range. The unit's rated voltage i s
single-phase 100/120/200/220/240VAC ±10X (max. 250V) at 50/60Hz.
*The rated voltage i s indicated on the specification and name plate located
beside the input connector on the rear panel.
*See the Maintenance sect ion (7-2. Changing the supp ly voltage) f o r
information on how to chang the rated voltage.
2) Precautions for connection of output terminals
* T h i s unit i s a floating type power supply. For ordinary use, be sure that
the MASTER/SLAVE switch on the rear panel i s s e t to MASTER, and that
either the ( + ) output terminal or the ( - ) output terminal i s connected
to the GND terminal (case GND) v i a the shorting bar.
3) Output current value setting
*To set the constant current value, s h o r t - c i r c u i t output terminals ( + )
and ( - ) and deliver the output current.
4) Set-up envi ronment
*Be sure to use this unit within the specified ambient temperature range of
0 to 40 deg C.
••Because the unit i s cooled by natural convection, do not place objects on
top, place the unit on or near any heat-emitting device, or use multiple
units in any stacked configuration. Also use the unit in an environment
that i s as well cross-ventilated as possible.
7