34
TK-2118
TK-260
:K, K2
Use the KPG-69D programming software for adjustment of the next item in PC MODE (see page 10).
Squelch Level, S meter Level, Lo Power, QT Deviation, DQT Deviation, and Battery warning.
ADJUSTMENT
Method
Adjust to center frequency
Rectify the waveform to square
wave
Adjust it to 2W
Adjust it to
±
4.2kHz
Check
Adjust it to 0.75kHz
Adjust it to
±
0.65kHz
Adjust it to 2.5kHz.
Parts
VR1
VR301
PC key
VR302
PC key
PC key
VR303
PC key
Specifications/
Remarks
within
±
100Hz
within
±
0.1W
±
100Hz
±
2.2kHz~3.8kHz
±
0.05Hz
±
0.05Hz
±
100Hz
Terminal
ANT
Test equipment
Frequency
counter
Modulation analyzer
Power meter
Current meter
Modulation
analyzer 15kHz LPF
AG, AF. V. M
Modulation
analyzer 3kHz LPF
Modulation
analyzer 3kHz LPF
Modulation
analyzer 15kH LPF
Condition
1) CH: TX center
PTT: ON
1) CH: TX center
1) CH TX center
CH TX low
CH TX high
1) CH: TX center
AG: 1kHz/50mV
1) CH: TX center
AG: 1kHz/5mV
1) CH: TX center
CH: TX low
CH: TX high
QT: 151.4Hz
1) CH: TX center
CH: TX low
CH: TX high
DQT:023N
1) CH TX center using [9] key
1) Battery terminal: 5.5V
Transmitter section
Item
1. Transmit
frequency
2. DQT/QT
Balance
3. Lo Power
(PC Mode)
4. MAX DEV
5. MIC
sensitivity
6. QT
Deviation
(PC Mode)
7. DQT
Deviation
(PC Mode)
8. DTMF
Deviation
9. Battery
Warning
(PC Mode)
Measurement
Adjustment
Parts
TC1
TC2
Method
1.5V(C), 1.2V(C2)
2.2V(C), 1.0V(C2)
Check
Specifications/
Remarks
±
0.1V
±
0.1V
less than 4.5V
Terminal
CV
Test equipment
Digital voltmeter
Condition
1) Power supply voltage
Battery teriminal:7.5V
1) CH: TX low
2) CH: RX low
3) CH: TX high
4) CH: RX high
Section common to the transmitter and receiver (VCO)
Item
1. Setting
2. VCO lock
voltage
Measurement
Adjustment
Parts
TC3,TC4
L22
PC key
PC key
Method
Adjust the spectram waveform.
Adjust to the MAX AF level
Vol. knob position at 12 o'clock
Check
Adjust to open the squelch.
Adjust to open the squelch.
Adjust to Full digit
Adjust to one digit
Specifications/
Remarks
SINAD: 12dB or
higher
Terminal
ANT
SP
ANT
Test equipment
Tra generator
Spectrum analyzer
SSG
Oscilloscope
AF. V. M
Distortion meter
SSG
Condition
1) CH: RX center
1) CH: RX center
SSG output: -53dBm(501
µ
V)
MOD: 1kHz
DEV:
±
3.0kHz
1) CH: RX center
CH: low
CH: high
SSG ouput: -116dBm(0.35
µ
V)
MOD: 1kHz
DEV:
±
3.0kHz
1) CH: RX center
2) Level 9
SSG output: -116dBm(0.35
µ
V)
3) Level 1
SSG output: -123dBm(0.16
µ
V)
1) CH: RX center
2) Full digit
SSG output: -110dBm(0.7
µ
V)
3) one Digit
SSG output: -120dBm(0.2
µ
V)
Receiver Section
Item
1. Band-
pass filter
2. AF level
3. Sensitivity
4. Squelch
Level
(PC Mode)
5. S meter
Level
(PC Mode)
Measurement
Adjustment