65
TK-5710
(
B
)
/5710H
(
B
)
ADJUSTMENT
9. QT deviation 1) Adj item:[W QTW]
Power meter Rear
ANT
Front
[PF3],
0.75kHz
±50Hz
adjust
Adjust:[***]
Deviation
panel
panel
[PF4]
•Wide
Deviation meter filter
meter
LPF:3kHz
Oscilloscope Front
MIC jack
HPF:OFF
AG
panel
2) Adj item:[WL QTW]
t
AF VTVM
[WC QTW]
t
[WH QTW]
Adjust:[***]
PTT:ON
Press [PF5] to store the adjust-
ment value after adjustment.
•Narrow
3) Adj item:[N QTN]
0.35kHz
±25Hz
Adjust:[***]
4) Adj item:[WL QTN]
t
[WC QTN]
t
[WH QTN]
Adjust:[***]
PTT:ON
Press [PF5] to store the adjust-
ment value after adjustment.
10.DQT
1) Adj item:[W DQTW]
0.75kHz
±50Hz
deviation
Adjust:[***]
adjust
Deviation meter filter
•Wide
LPF:3kHz
HPF:OFF
2) Adj item:[WL DQTW]
t
[WC DQTW]
t
[WH DQTW]
Adjust:[***]
PTT:ON
Press [PF5] to store the adjust-
ment value after adjustment.
•Narrow
3) Adj item:[N DQTN]
0.35kHz
±25Hz
Adjust:[***]
4) Adj item:[WL DQTN]
t
[WC DQTN]
t
[WH DQTN]
Adjust:[***]
PTT:ON
Press [PF5] to store the adjust-
ment value after adjustment.
11.DTMF
1) Adj item:[W DTMW]
3.0kHz
±100Hz
deviation
Adjust:[***]
adjust
Deviation meter filter
•Wide
LPF:15kHz
HPF:OFF
PTT:ON
Press [PF5] to store the adjust-
ment value after adjustment.
•Narrow
2) Adj item:[N DTWN]
1.5kHz
±50Hz
Adjust:[***]
PTT:ON
Press [PF5] to store the adjust-
ment value after adjustment.
Measurement
Adjustment
Item
Condition
Test-
Unit
Terminal
Unit
Parts
Method
Specifications/Remarks
equipment