TK-7100
35
ADJUSTMENT
3. Squelch 1 1) CH : RX low (Wide)
PC key
Adjust to open the squelch
CH : RX center (Wide/Narrow)
CH : RX high (Wide)
2) SSG output
: –120dBm (0.22
µ
V) (Wide)
: –119dBm (0.25
µ
V) (Narrow)
Mod : 1kHz
Dev :
±
3.0kHz (Wide)
Dev :
±
1.5kHz (Narrow)
Item
Condition
Test equipment
Terminal
Parts
Method
Specifications/
Remarks
Measurement
Adjustment
Transmitter Section
1. Frequency 1) CH : TX center
Frequency counter
ANT
PC key
Adjust to center frequency
Within
±
100Hz
2) Transmit
2. Maximum 1) CH : TX high
Power meter
28W
±
1W
power
2) Transmit
check
3. High
1) CH : TX low
25W
±
1.0W
power
CH : TX low’
CH : TX center
CH : TX high’
CH : TX high
2) Transmit
4. Low
1) CH : TX low
5W
±
1.0W
power
CH : TX low’
CH : TX center
CH : TX high’
CH : TX high
2) Transmit
5. DQT
1) CH : TX low (Wide)
Modulation analyzer
Adjust the waveform as below
balance
CH : TX center (Wide/Narrow)
or Linear detector
CH : TX high (Wide)
(LPF : 3kHz)
2) Transmit
Oscilloscope
6. MAX
1) CH : TX low (Wide)
Modulation analyzer
ANT
±
4.0kHz (Wide)
±
50Hz
balance
CH : TX center (Wide/Narrow)
or Linear detector
MIC
±
2.0kHz (Narrow)
CH : TX high (Wide)
(LPF : 15kHz)
According to the large +, –
2) AG : 1kHz/50mV
Oscilloscope
3) Transmit
AG
7. MIC
1) CH : TX center (Wide/Narrow)
AF V.M
Check
±
3kHz
±
0.2kHz
sensitivity 2) AG : 1kHz/5mV
(Wide)
3) Transmit
±
1.5kHz
±
0.1kHz
(Narrow)
8. DQT
1) CH : TX low (Wide)
Modulation analyzer
±
0.75kHz (Wide)
±
0.05kHz
deviation
CH : TX center (Wide/Narrow)
or Linear detector
±
0.35kHz (Narrow)
CH : TX high (Wide)
(LPF : 3kHz)
2) Transmit
Oscilloscope
9. QT
1) CH : TX low (Wide)
±
0.75kHz (Wide)
±
0.05kHz
deviation
CH : TX center (Wide/Narrow)
±
0.35kHz (Narrow)
CH : TX high (Wide)
2) Transmit
10. DTMF
1) CH : TX center (Wide/Narrow)
±
3.0kHz (Wide)
±
0.2kHz
deviation
2) Transmit
±
1.5kHz (Narrow)
Item
Condition
Test equipment
Terminal
Parts
Method
Specifications/
Remarks
Measurement
Adjustment