53
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-760G/
(
N
)
/762G/
(
N
)
8. MIC
1) Set test mode
Power meter Rear
ANT
Check
±
2.4kHz~
±
3.4kHz (Wide)
seisitivity
CH : CH1 - Sig1
Deviation
panel
±
1.2kHz~
±
1.7kHz (Narrow)
check
AG : 1kHz/5mV
meter
PTT : ON
Oscilloscope
AF VTVM
Front
MIC
9. QT deviation 1) Set test mode
AG
panel
Front
CH /
0.75kHz (Wide)
±
50Hz
• Wide/
Select “FQT” in tuning mode.
panel
0.35kHz (Narrow)
Narrow
“_
.
FQT”
Deviation meter filter
LPF : 3kHz, HPF : OFF
PTT : ON
Adjust [***]
2) “_
.
F
.
Q
.
T”
PTT : ON
Adjust [***]
3) “_
.
F
.
Q
.
T
.
_
.
”
PTT : ON
Adjust [***]
• Semi wide 4) “_FQT***
.
”
0.60kHz
PTT : ON
Adjust [***]
10. DQT
1) Set test mode
Front
CH /
0.75kHz (Wide)
±
50Hz
deviation
Select “FDQT” in tuning mode.
panel
0.35kHz (Narrow)
• Wide/
“F
.
DQT”
Narrow
Deviation meter filter
LPF : 3kHz, HPF : OFF
PTT : ON
Adjust [***]
2) “F
.
D
.
Q
.
T”
PTT : ON
Adjust [***]
3) “F
.
D
.
Q
.
T
.
_
.
”
PTT : ON
Adjust [***]
• Semi wide 4) “FDQT***
.
”
0.60kHz
PTT : ON
Adjust [***]
11. DTMF
1) Set test mode
Front
CH /
3.0kHz (Wide)
±
0.1kHz (Wide)
deviation
Select “DTMF” in tuning mode.
panel
1.5kHz (Narrow)
±
0.05kHz (Narrow)
• Wide/
Deviation meter filter
Narrow
LPF : 15kHz, HPF : OFF
PTT : ON
Adjust [***]
• Semi wide 2) “DTMF***
.
”
2.4kHz
±
0.1kHz
PTT : ON
Adjust [***]
12. TONE
1) Set test mode
Front
CH /
3.0kHz (Wide)
±
0.1kHz (Wide)
deviation
Select “TONE” in tuning mode.
panel
1.5kHz (Narrow)
±
0.05kHz (Narrow)
• Wide/
Deviation meter filter
Narrow
LPF : 15kHz, HPF : OFF
PTT : ON
Adjust [***]
• Semi wide 2) “TONE***
.
”
2.4kHz
±
0.05kHz
PTT : ON
Adjust [***]