ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-782
7. Maximum
1) Set test mode
Power meter Rear
ANT
4.1kHz (Wide)
+0Hz/–50Hz (Wide/Narrow)
deviation
Connect AG to the MIC
Deviation
panel
2.05kHz (Narrow)
terminal.
meter
(According to the
Select “MAX” in tuning mode. Oscilloscope
, –)
“nL MAX”
AG : 1kHz/40mV
AF VTVM
Front
MIC
Deviation meter filter
AG
panel
LPF : 15kHz
HPF : OFF
De-emphasis : OFF
PTT : ON
2) “nC MAX”
PTT : ON
3) “nH MAX”
PTT : ON
4) “w MAX”
PTT : ON
8. MIC
1) Set test mode
Check
±
3kHz
±
0.2kHz (Wide)
seisitivity
CH : CH1 - Sig1
±
1.5kHz
±
0.05kHz (Narrow)
check
AG : 1kHz/4mV
PTT : ON
9. QT deviation 1) Set test mode
0.75kHz (Wide)
±
50Hz (Wide/Narrow)
Select “QT” in tuning mode.
0.35kHz (Narrow)
“nL QT”
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) “nC QT”
PTT : ON
3) “nH QT”
PTT : ON
4) “w QT”
PTT : ON
10. DQT
1) Set test mode
0.75kHz (Wide)
±
50Hz (Wide/Narrow)
deviation
Select “DQT” in tuning mode.
0.35kHz (Narrow)
“nL DQT”
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) “nC DQT”
PTT : ON
3) “nH DQT”
PTT : ON
4) “w DQT”
PTT : ON
72