22
TK-785
TX-RX Unit (X57-6142-71) (A/2) : K,E
Ref. No.
Use / Function
Operation / Condition
IC1
DC amp
FC, TCXO control
IC2
DET amp
External DEO, internal DEO
IC3
Amp/Summing amp
DI / DI and MO addtion
IC4
Analog switch
DI switch
IC5
A/D converter
PC, TV, FC, AFO, BEEP, TO, MO control
IC6
DC amp
PC
IC7
Shift register
HNC, H/L, TOF, CODE3, CODE4,
PA control
IC8
Shift register
AM, LOK, STR, DM, OPT, CODE1,
CODE2 control
IC9
5V AVR
External 5C
IC10
AF power amp
IC11
FM IF DET
Quadrature detector, 2nd mixer,
OSC, IF amplifier, RSSI
IC12
5V AVR
5C
IC13
9V AVR
9C
IC14
8V AVR
8C
IC15
Flip-flop
Power on/off control
IC201
DC amp
TV
IC202
Mixer
DBM
IC300
PLL
Reference 16.8MHz.
PLL lock : LD “H”
IC400
Power module
RF power 10W (K), 15W (E)
IC401
Short protection
Q1
DC switch
When PTT on CN1 is “H”,
DI on CN1 is muted
Q2
Ripple filter
8CL
Q3
Ripple filter
9CL
Q4
HOR switch
IGN
Q5
HOR SW control
IGN
Q6
HOR SW control
Active while HNC is “H”
Q7
Buffer amp
HT
Q8
AF mute
Avtive while AM1 is “H”
Q9
AF mute
Active while power switch is off
Q10
8R SW control
Active while T/R is “H”
Q11
8R switch
Active while Q10 is active
Q12
8T switch
Active while Q13 is active
Q13
8T SW control
Active while KEY is “H”
Q15
IF amp
44.85MHz
Q16
DET output level switch
No function
Q17
PC switch
Active while TX
Q18
DET mute
Active while KEY is “H”
Q19
APC
APC driver
Q20
APC
APC predriver
Q21
APC control
Q22
TOF switch
Active while TOF is “H”
DESCRIPTION OF COMPONENTS
Ref. No.
Use / Function
Operation / Condition
Q23
W/N switch
No function
Q24
W/N switch
No function
Q25
TOF switch
Active while Q22 is on
Q26
Inverter
Active while power switch is “L”
Q27
SB switch
Active while Q28 is on
Q28
SB SW control
Active while Q30 is on, and Q31 is off
Q29
H/L switch
Active while RF power is High
Q30
SB SW control
Active while power switch is on
Q31
SB SW control
Active while power supply voltage
is more than 20V
Q32
DET mute
Active while TX
Q202
LNA
Q203
RF amp
Power module predrive
Q204
RF amp
Power module drive
Q300
Buffer amp
PLL
Q301,302
Active filter
Q401
Short protection
Power module protection
Q402
W/N switch
No function
Q403
W/N switch
No function
D1~6
Protection
D7
HOR protection
D8,9
Protection
D11
OR gate
AF mute
D12~14
Protection
D15
HT switch
D16
Reverse protection
D17
Protection
D20
Reverse protection
IGN
D21
Protection
5V (IGN)
D22,23
W/N switch
No function
D24
Over current
protection
D26
Reverse protection
D27
Power detection
D28
Protection
D30
Power detection
D31
Reverse protection
D32
Surge absorption
B
D34
Protection
Active while power supply voltage
is more than 20V
D35
Charge
DEO
D37
Reverse protection
D206~208
BPF tune
D209,210
Usable temperature
range
D211
ANT swtich
Active while TX
D212
ANT switch