47
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-785
Receiver Section
1. Discriminator 1) Set test mode
SSG
Rear
ANT
TX-RX
L6
AF output voltage
CH : CH1 - Sig1
panel
(A/2)
maximum.
SSG output : –53dBm
AF VTVM
ACC
AF : 1.4V/4
Ω
Oscilloscope
(EXT.SP)
2. Sensitivity
1) Set test mode
SSG
ANT
Adjust for
Select “SENS” in tuning mode.
maximum SINAD.
“L SENS”
AF VTVM
ACC
SSG freq’ : 217.05MHz
K,E
Distortion
(EXT.SP)
: 250.05MHz
M
meter
SSG output : –118dBm/0.31
µ
V
Oscilloscope
SSG MOD : 1.5kHz
AG
AF output : 1V/4
Ω
2) “C SENS”
Adjust for
SSG freq’ : 226.05MHz
K,E
maximum SINAD.
: 260.05MHz
M
3) “H SENS”
Adjust for
SSG freq’ : 234.95MHz
K,E
maximum SINAD.
: 269.95MHz
M
3. Squelch
1) Set test mode
Squelch must be
Select “L SQL” in tuning mode.
closed once.
SSG freq’ : 217.05MHz
K,E
Then adjust for
: 250.05MHz
M
squelch open point.
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 1.5kHz
2) “C SQL”
SSG freq’ : 226.05MHz
K,E
: 260.05MHz
M
3) “H SQL”
SSG freq’ : 234.95MHz
K,E
: 269.95MHz
M
4. RSSI (Low)
1) Set test mode
Writing values only.
Select “L LRSI” in tuning mode.
SSG freq’ : 217.05MHz
K,E
: 250.05MHz
M
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 1.5kHz
2) “C LRSI”
SSG freq’ : 226.05MHz
K,E
: 260.05MHz
M
3) “H LRSI”
SSG freq’ : 234.95MHz
K,E
: 269.95MHz
M