ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
50
TK-785
8. MIC
1) Set test mode
Power meter Rear
ANT
Check
±
1.5kHz
±
0.05kHz
seisitivity
CH : CH1 - Sig1
Deviation
panel
check
AG : 1kHz/4mV
meter
PTT : ON
Oscilloscope
9. QT deviation 1) Set test mode
AF VTVM
Front
MIC
0.35kHz
±
50Hz
Select “QT” in tuning mode.
AG
panel
“L QT”
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) “C QT”
PTT : ON
3) “H QT”
PTT : ON
10. DQT
1) Set test mode
0.35kHz
±
50Hz
deviation
Select “DQT” in tuning mode.
“L DQT”
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) “C DQT”
PTT : ON
3) “H DQT”
PTT : ON
11. DTMF
1) Set test mode
1.5kHz
±
0.1kHz
deviation
Select “DTMF” in tuning mode.
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
12. FFSK
1) Set test mode
1.5kHz
±
0.1kHz
deviation
Select “FFSK” in tuning mode.
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
13. TONE
1) Set test mode
1.5kHz
±
0.1kHz
deviation
Select “TONE” in tuning mode.
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON