ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
52
TK-860G/862G
3) “L
.
P
.
O
.
W”
Power mete Rear
ANT
Front
CH /
5.0W
±
0.5W
PTT : ON
panel
panel
Adjust [***]
4) “L
.
P
.
O
.
W
.
”
PTT : ON
Adjust [***]
5) “L
.
P
.
O
.
W
.
_
.
”
PTT : ON
Adjust [***]
5. Power check 1) Set test mode
Power meter Rear
ANT
Check
25W
±
1W, 8A or less
CH : CH1 - Sig1
panel
CH2 - Sig1
Ammeter
DC IN
CH3 - Sig1
PTT : ON
6. Modulation
1) Set test mode
Power meter Rear
ANT
Front
CH /
Make the de-
(Wide/Narrow)
balanced
MIC input : OFF
Deviation
panel
panel
modulation
• Wide
Select “BAL” in tuning mode. meter
waveform neat.
“_
.
BAL”
Oscilloscope
Deviation meter filter
LPF : 3kHz, HPF : OFF
AF VTVM
Front
MIC
De-emphasis : OFF
AG
panel
PTT : ON
Adjust [***]
2) “_
.
B
.
A
.
L”
PTT : ON
Adjust [***]
3) “_
.
B
.
A
.
L
.
_
.
”
PTT : ON
Adjust [***]
• Narrow
4) “_BAL***
.
”
PTT : ON
Adjust [***]
7. Maximum
1) Set test mode
3.95kHz (Wide)
K,M
±
50Hz (Wide/Narrow)
deviation
Connect AG to the MIC
3.85kHz (Wide)
K3
• Wide
terminal.
1.75kHz (Narrow)
Select “MAX” in tuning mode.
(According to the
“_
.
MAX”
, –)
AG : 1kHz/50mV
Deviation meter filter
LPF : 15kHz, HPF : OFF
De-emphasis : OFF
PTT : ON
Adjust [***]
2) “_
.
M
.
A
.
X”
PTT : ON
Adjust [***]
3) “_
.
M
.
A
.
X
.
_
.
”
PTT : ON
Adjust [***]
• Narrow
4) “_MAX***
.
”
PTT : ON
Adjust [***]