1-24 (No.RA035<Rev.001>)
4.6
Transmitter Section
3. Trans-
mit Assist
1) Adj item: [Transmit Assist]
2) Adj item: [Low], [Low’], [Center],
[High’], [High] PTT: Press [Trans-
mit] button.
Press [Apply All] button to store
the adjustment value.
Panel FPU
[<][>]
[V] indicator on the PC
window shows VCO
lock voltage.
Change the adjustment
value to get VCO lock
voltage within the limit of
the specified voltage.
Note:
Confirm the VCO lock
voltage approximate-
ly 3 seconds after the
adjustment value is
changed.
2.4~2.6V
Press [Apply All]
button to store
the adjustment
value after all
adjustment
point have been
adjusted.
4. Fre-
quency
1) Adj item: [Frequency]
PTT: Press [Transmit] button.
Press [Apply] button to store the
adjustment value.
2) Adj item: [High]
f. counter
Panel ANT
[FPU]
[<][>]
155.100MHz
155.099767~15
5.100233MHz
(±1.5ppm@
155.1MHz)
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
PC test mode
Test-
equipment
Unit Terminal Unit Parts
Method
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
PC test mode
Test-
equipment
Unit Terminal Unit Parts
Method
1. Ramp Off-
set
1) Adj item: [Ramp Offset]
2) Adj item: [Low], [Low’],
[Center], [High’], [High]
Panel
Panel [FPU]
[<][>]
Write the value as followings.
1
Press [Apply All] button to store the ad-
justment value after all adjustment points
have been adjusted.
2. High
transmit
power (Bat-
tery voltage :
7.5V)
1) Adj item:
[High Transmit Power]
2) Adj item: [Low], [Low’],
[Center], [High’], [High]
PTT: Press [Transmit] button.
Press [Apply All] button to
store the adjustment value.
Power
meter
Ammeter
Panel ANT
Panel [FPU]
[<][>]
5.0W
±0.2W
2.0A or less
Press [Apply] but-
ton to store the
adjustment value
whenever each
adjustment points
have been adjust-
ed.
3. Low trans-
mit power
(Battery volt-
age :7.5V)
1) Adj item: [Low Transmit
Power]
2) Adj item: [Low], [Low’],
[Center], [High’], [High]
PTT: Press [Transmit] button.
Press [Apply All] button to
store the adjustment value.
Power
meter
Ammeter
Panel ANT
Panel [FPU]
[<][>]
1.0W
±0.05W
1.0A or less
Press [Apply] but-
ton to store the
adjustment value
whenever each
adjustment points
have been adjust-
ed.