TK-U100
(
V
)
36
LEVEL DIAGRAM /
电平图
T
ransmitter Section /
发射部分
Receiver Section /
接收部分
To make measurements in the AF section, connect the AC level meter.
(ANT input : –53dBm, 1kHz FM, 1.5kHz DEV (Narrow).)
In the RF section, use a high impedance probe. (ANT input : –53dBm, MOD off.)
AG is set to the MIC input becomes 1.5kHz DEV, at 1kHz MOD. (Narrow)
To make measurements in the AF section, connect the AC level meter.
In the RF section, use a 1000pF coupling capacitor
要在AF段进行测量,请连接交流电平表。
(ANT输入∶-53dBm,1kHz FM,1.5kHz频偏(窄带)。)
在RF段,请使用高阻抗探针。(ANT输入∶-53dBm,MOD关。)
AG被设为麦克风输入,为1.5kHz频偏在1kHz调制。(窄带)
要在AF段进行测量,请连接交流电平表。
在RF段,请使用1000pF耦合电容。
FM IF
SYSTEM
DAC
SG
–53dBm
50
Ω
ANT
–58.0dBm
–74.8dBm
–67.6dBm
–55.0dBm
–52.6dBm
–47.5dBm
–60.8dBm
–33.47dBm
174mVrms
71mVrms
1.9Vrms
1.9Vrms
1.9Vrms
C250
C247
C240
C237
C224
C221
C216
C328
C320
C302
+
SP
500mW
Q306
Q302
IC302
IC300
IC200
Q202
XF200
MIXER
Q203
Q204
RF (CENTER FREQUENCY)
IF1 (38.85MHz)
IF2
450kHz
AF (1kHz)
AF
AMP
IC300
DAC
C29
–11.2dBm
VCO
C33
5.2dBm
C42
2.2dBm
3.0dBm
C112
18.5dBm
C127
36.2dBm
ANT
50
Ω
MIC
15.1mVrms
216mVrms
38.2dBm
C100
11.8dBm
C108
Q5
Q6
RXLo
D200
D100
Q100
Q101
Q102
AF (1kHz)
RF (CENTER FREQUENCY)
R313
Q4
Summary of Contents for TK-U100
Page 44: ...TK U100 V 40 MEMO 笔记 ...