INSTALLATION
RX M ODIFICATION FOR EXTERNAL
PRESELECTOR FILTER
This model may be modified to use an external pre-selector
filter.
1
Remove the RX cover panel.
2
Remove the flat clip spring from IC4 and L16
3
Remove the 11 screws from the RX unit and the 10 screws
from the shield case.
4
Remove the jumper (R179) from the reverse side of the RX
unit.
5
Insert an SMB receptacle (E04-0409-05) at CN10. Solder
the 5 leads in place.
6
Replace the screws on the RX unit and shield case, and the
flat clip spring on IC4 and L16.
7
Move the RX IN signal cable (from the back panel) from
CN1 to CN10.
8
Connect a tracking generator signal to RX IN, then use a
spectrum analyzer to read the output at CN2 while adjusting
L16 for the proper response.
9
Next, adjust IF , squelch , and RSSI.