Section 7
Routing
7-2
02/09
heavy duty tie straps 0.50in (12.7mm) wide (Tyton T255RohIR or similar) shall be used
whenever hD mounts are specified, although 0.25in (6.4mm) tie straps may be used in
some specified applications.
figure 7-4.
Heavy Duty (HD) Mount
Excess of material: More than 3 inches of slack for every 14 inch section of hose routing, except for air conditioner
hoses See section 4 1 3 for air conditioner hose requirements
Shortness of material:
Less than 1 inch of slack on a 14 inch section of hose routing
routing requirementS
Wiring
Electrical ground wire terminals must be securely attached and the complete terminal surface must contact a clean bare
metal surface See R414-558 for grounding wire connection practice Apply electrical contact corrosion inhibitor Nyogel
759G grease (made by william F Nye, Inc , New Bedford, MA) per R414-558
Don’t bend wires or use tie straps within 3 inches (75 mm) of (connected) wire connectors or plugs
Wires in Bundles
Electrical wires (other than the exceptions covered below) running parallel with air or coolant hose bundles, may be in-
cluded in the bundle if they are isolated from the hoses with a covering of convoluted plastic tubing
exceptionS:
Battery cables (including jump start cables) may be bundled with or tied to the charging wire harness
They shall
not
be bundled with or tied directly to any other components, including hoses, wires, or
bundles. They shall be separated from other routed components using butterfly ties at intervals not
exceeding 14 inches (356 mm) Battery strap (w84-1000) tie down shall be used without exception to
secure battery cables to frame mounted or other major component (e g engine, tmsn, etc ) mounted
standoffs at intervals not exceeding 14 inches (356 mm) The (positive) battery cable shall be covered
with convoluted plastic tubing from terminal to terminal
110/220 volt wires for engine heaters, oil pan heaters, transmission oil heaters and battery pad
warmers, shall
not
be included in any hose/wire bundle with a fuel hose Individual heater wires not
in a bundle shall be separated from other components by using butterfly clamps or butterfly ties at inter-
vals not exceeding 14 inches (356 mm) Heater wires with a secondary covering shall be covered with
convoluted tubing whether they are in bundles or not
note:
Summary of Contents for T470
Page 1: ...Kenworth T470 Body Builder Manual ...
Page 2: ......
Page 3: ...Kenworth T470 Body Builder Manual ...
Page 8: ......
Page 10: ......
Page 14: ......
Page 38: ...Section 3 Dimensions 08 09 3 24 Watson Chalin Atlas 22 5K Non Steerable Pusher ...
Page 74: ......
Page 91: ...08 06 Section 6 Electrical 6 17 5 Push down to unhook connector from switch ...
Page 109: ...08 09 ...
Page 110: ...08 09 Kenworth Truck Company P O Box 1000 Kirkland WA 98083 425 828 5000 ...